Function Description
WAGO-I/O-SYSTEM 750
750-375 PROFINET IO advanced Fieldbus Coupler
Manual
Version 1.1.0
3
IOS connection (TCI CC3)
The SEDI is called up directly via the communication server of the
configuration environment.
More Information on the TCI conformance classes!
More information on the TCI conformance classes is available in the quickstart
guide of the PROFINET IO fieldbus coupler. You can download the quickstart
guide free of charge from the WAGO Internet site at:
More Information on the iPar server!
More information on the iPar server is available in the manuals for PROFIsafe
safety modules of the 750 and 753 series. You can download these manuals free
of charge from the WAGO Internet site at:
7.11
Controlling Digital and Analog Output Modules per
PROFIenergy
PROFIenergy is an energy management profile based on the communication
mechanisms of PROFINET IO.
Encouraged by the Automation Initiative of German Automobile Manufacturers
(AIDA), a specification was developed by PROFIBUS & PROFINET
International and standardized in the form of a general profile.
The PROFIenergy implementation of the fieldbus coupler is based on profile
version 1.0.
PROFIenergy devices can be switched between predefined energy saving modes
using standardized commands. The switching characteristics do not fall to the
specification, but are manufacturer specific.
7.11.1
Hardware
The concept of the energy saving measures is based on PROFIenergy-specific
substitute values of the digital and analog output modules available to you when
using the respective PROFIenergy submodule for the configuration. These
submodules are marked with "PE" in the designation. You can configure the
PROFIenergy substitute values within the framework of the available output value
range. Currently, parameterization of one PROFIenergy substitute value per signal
channel is possible.