38 Commissioning
WAGO-I/O-SYSTEM 750 XTR
750-630/040-001 SSI Interface Adjust XTR
Manual
Version 1.1.0
Table 23: Selection Boxes for the Parameterization Dialog
Selection box
Possible settings
Baud rate
250.0 kHz / 125.0 kHz
*)
/ 100.0 kHz /
83.0 kHz / 71.0 kHz / 62.5 kHz
PI-Length
0 bit ... 24 bit
*)
... 32 bit (numeric input field)
Var. Frame Length
**)
Not used
*)
Variable data frame disabled
1
Bit / … /
32 Bit
Length of the variable data frame for
data exchange between the I/O
module and SSI absolute encoder
Output Format
Standard
(see mapping tables in the fieldbus
coupler/controller manuals)
Alternative
*)
(see mapping tables in the fieldbus
coupler/controller manuals)
Synchronous Operation
Disable
*)
Synchronous operating mode of the
SSI absolute encoder disabled
Enable
Synchronous operating mode of the
SSI absolute encoder enabled
Data transmission is synchronous
with the read cycle of the local buses.
Gray-Dualcode
Conversion
Disable
Gray-dualcode conversion disabled
Enable
*)
Gray-dualcode conversion enabled
Single-Turn Evaluation
Disable
*)
Single-turn evaluation disabled
Enable
Single-turn evaluation enabled
(13 bit)
Frame Error
Disable
Frame error disabled
Enable
*)
Frame error enabled
Power Fail Bit
(PFB)
Disable
*)
Power fail bit disabled
Enable
After the last valid bit, whether the
data line sends a zero signal is
checked.
*)
Default settings
**)
Only adjustable at 125 kHz