Table 38: Possible errors during the backup function
Possible error
Procedure
Error message
Solution
Memory card is full
The copy function is
cancelled. Device
settings and files in the
/copy/ directory and the
subdirectories are not
saved completely on
the memory card.
Blink code of the I/O
LED
(error code 14, error
argument 4) until the
error is eliminated.
Replace the memory
card with a new one,
then restart the backup
function.
Create storage space on
the memory card with
the PC.
Memory card is write-
protected.
Copying is not
possible, the backup
function is cancelled
and the memory card
remains as it was.
Blink code of the I/O
LED
(error code 14, error
argument 6) until the
error is eliminated.
Remove the memory
card, remove the write
protection, insert the
card again, then restart
the backup function.
Manual interrupt
The copy function is
cancelled. Device
settings and files in the
/copy/ directory and the
subdirectories are not
saved completely on
the memory card.
Blink code of the I/O
LED
for 30 seconds (error
code 14, error
argument 2) or until the
error is eliminated.
Insert memory card,
then restart the backup
function.
General internal error
The copy function is
cancelled. Device
settings and files in the
/copy/ directory and the
subdirectories are not
saved completely on
the memory card.
Blink code of the I/O
LED
(error code 14, error
argument 6).
If necessary, restart
function and device.
7.4.3
Restore Function (Loading of Device Settings from the
Memory Card)
The fieldbus nodes and the SPS program are in operation and the memory card is
plugged in.
On the "Features" Web page, start the "Restore device settings from removable
disk" function in order to load the device settings from the memory card to the
internal drive during normal operation.