46
Commissioning
WAGO-I/O-SYSTEM 750
750-921
Bluetooth
®
Adapter
Manual
Version 2.0.1, applicable from FW Version 02
7.3
Example: Establish a Connection between 2 WSAs
1.
Execute the
AT CON OPEN
command on the command interface of the 2.
WSA to establish a connection to the first, pre-configured WSA.
2.
Wait for the
00 SUCCESS
success message.
3.
When operating the command interface from a PLC:
Close the interface command via the
AT LOGOUT
AT command to send
data via the wireless connection instead of displaying it in the command
interface.
When operating the command interface via the SPP “CONFIG”
service:
You can close or maintain the connection to the SPP “CONFIG” service if
desired.
“DATA” data exchange and “CONFIG” configuration can occur
simultaneously!
The WSA allows simultaneous data exchange via the SPP “DATA” service and
operation of the command interface via the SPP “CONFIG” service. This allows
you, for example, to query diagnostic information with
AT STATUS STATS
or
AT STATUS CON
.
For simultaneous radio connection with both SPP services, the LED lights up
continuously and data transfer is no longer indicated by flickering.
Data can now be exchanged between the 2 WSAs via the
Bluetooth
®
connection.
Data sent on one service interface (or by the PLC) is received on the other service
interface and vice versa.