32
Device Description
EPSITRON® COMPACT Power
787-1202 / -1212 / -1216 / -1226 EPSITRON® COMPACT Power
Manual
Version 1.0.0
Pos: 41.5 /Serie 787 (
EPSITRON
)/Ger ätebeschrei bung/N or men und Richtli nien/N ormen 787-12xx - Ei nleitung - EM V @ 19\mod_1397742075189_21.docx @ 152174 @ @ 1
The devices 787-1202 / -1212 / -1216 / -1226 comply with the following EMC
standards:
Pos: 41.6 /Serie 787 (
EPSITRON
)/Ger ätebeschrei bung/N or men und Richtli nien/N ormen 787-12xx - Störfestig keit EMV @ 19\mod_1397742159386_21.docx @ 152177 @ @ 1
Table 18: EMC – Immunity to Interference
Standard
Test value
Electrostatic discharge
• EN 61000
-4-2
6 kV (contact discharge)
8 kV (air discharge)
High-frequency electromagnetic fields
• EN 61000
-4-3 + A1 + A2
10 V/m (0.08 GHz … 1 GHz)
Criterion A
Fast electrical transient disturbances/burst
•
EN 61000-4-4
±
2 kV, 5 kHz, 5 min, direct coupling
Criterion A (
±
1 %)
Surge voltage/surge
• EN 61000
-4-5
Input (L-N): 1 kV, 2 Ohm, 18 µF, Differential
Mode
Output (+ -) : 0.5 kV, 2 Ohm, 18 µF, Differential
Mode
Conducted disturbances, induced by high-frequency fields
• EN 61000
-4-6
10 V (0.15 MHz … 80 MHz)
Criterion B (
±
10 %)
Magnetic fields with electrical frequencies
• EN 61000
-4-8
30 A/m
Voltage dips, AC input voltage
• EN
61000-4-11
Test level
% U
T
*
Voltage drop
% U
T
*
Duration
(in periods)
Criterion
0
100
1
B
40
60
10
C
70
30
25
C
Voltage interruptions, AC input voltage
• EN
61000-4-11
Test level
% U
T
*
Voltage drop
% U
T
*
Duration
(in periods)
Criterion
0
100
250
C
*
U
T
= minimum value of the input voltage range (see section “Device Description” > “Technical
Data”).