Compact Power
Connect Devices 45
787-1211 DC power supply, 12 V
Manual
Version 1.
1
.0
1.
Place the unlocking tool (3) onto the locking latch (1).
2.
Insert the unlocking tool fully.
Wedge opens locking latches (also see the figure “Removing the female
connector with wiring”).
3.
Grip underneath the protruding rim of the female connector (2).
4.
Pull out the female connector.
If you do not have an unlocking tool available, you can also remove the female
connector with a WAGO operating tool or a screwdriver
Do not insert the tool in the ventilation slots!
Components inside the device may be damaged if the blade of an operating tool
enters the ventilation slots. This may lead to serious damage with a risk of injury
caused by malfunction, overheating or electric shock!
When using a screwdriver or an actuation tool, ensure correct positioning
between the locking latch and the female connector!
Proceed as follows:
1.
Push the locking latch (1) away from the female connector using the
screwdriver or operating tool.
2.
Grip underneath the protruding rim of the female connector (2).
3.
Pull out the female connector.
5.1.2.2.2 Removing the Female Connector with Wiring
Proceed as follows to remove the female connector with the unlocking tool:
1.
Place the unlocking tool (3) onto the locking latch (1).
2.
Insert the unlocking tool fully.
Wedge opens locking latches.
3.
Pull out the unlocking tool together with the cables and the female
connector.
If you do not have an unlocking tool available, you can also remove the female
connector with a WAGO operating tool or a screwdriver