WAGO-ETHERNET-Accessories 852
Assembly
21
852-111 5 Port 100BASE-TX Industrial Eco Switch
Manual
Version 1.0.0
4.4 Connect
devices
Pos: 8.5 /Serie 852 (Ethernet-Zubehör)/Montieren/Anschluss Spannungsversorgung 852-111, 112 @ 4\mod_1236929741531_21.doc @ 28363
4.4.1 Supply
voltage
The Industrial Eco Switch uses a DC power supply of 18 … 30 V DC.
The primary power connection is provided via a terminal block located at the top
of the Industrial Eco Switch.
The terminal block is composed of three contact pins and can be inserted and
removed easily by hand to connect to the three pin terminal block (male contacts
located on the body of the Switch).
1
Check the front panel LEDs as the device is powered on to verify that the
Power LED is lit. If not, check that the power cable is correctly and securely
plugged in.
2
PWR +/- conductors:
To connect or disconnect the conductors, actuate the spring directly in the
female connector using a screwdriver or an operating tool and insert or
remove the conductor.
3
If the terminal block is not already inserted into the block receptor of the
Switch, do so now.
Pos: 9 /Dokumentation allgemein/Gliederungselemente/---Seitenwechsel--- @ 3\mod_1221108045078_0.doc @ 21810