background image

WAGO-ETHERNET-Accessories 852 

Important Notes 

852-111 5 Port 100BASE-TX Industrial Eco Switch 

 

 

Manual 

 

Version 1.0.0  

 

 

Pos: 2.1 /Alle Serien (Allgemeine Module)/Überschriften für alle Serien/Wichtige Erläuterungen - Überschrift 1 @ 4\mod_1241428899156_21.doc @ 32170 

 

1 Important 

Notes 

Pos: 2.2 /Alle Serien (Allgemeine Module)/Wichtige Erläuterungen/Einleitung Wichtige Erläuterungen @ 3\mod_1221059818031_21.doc @ 21717 

 

This section includes an overall summary of the most important safety re-
quirements and notes that are mentioned in each individual section. To protect 
your health and prevent damage to devices as well, it is imperative to read and 
carefully follow the safety guidelines. 

Pos: 2.3 /Alle Serien (Allgemeine Module)/Wichtige Erläuterungen/Rechtliche Grundlagen @ 3\mod_1221060626343_21.doc @ 21726 

 

1.1 Legal 

Bases 

Pos: 2.4 /Alle Serien (Allgemeine Module)/Wichtige Erläuterungen/Änderungsvorbehalt @ 3\mod_1221060036484_21.doc @ 21720 

 

1.1.1 

Subject to Changes 

WAGO Kontakttechnik GmbH & Co. KG reserves the right to provide for any 
alterations or modifications that serve to increase the efficiency of technical 
progress. WAGO Kontakttechnik GmbH & Co. KG owns all rights arising from 
the granting of patents or from the legal protection of utility patents. Third-party 
products are always mentioned without any reference to patent rights. Thus, the 
existence of such rights cannot be excluded. 

Pos: 2.5 /Serie 852 (Ethernet-Zubehör)/Wichtige Erläuterungen/Personalqualifikation @ 3\mod_1222346340968_21.doc @ 22264 

 

1.1.2 Personnel 

Qualification 

All sequences implemented on Series 852 devices may only be carried out by 
electrical specialists with sufficient knowledge in automation. The specialists 
must be familiar with the current norms and guidelines for the devices and 
automated environments. 

All changes to the controller should always be carried out by qualified personnel 
with sufficient sufficient skills in PLC programming. 

Pos: 2.6 /Serie 852 (Ethernet-Zubehör)/Wichtige Erläuterungen/Bestimmungsgemäße Verwendung @ 3\mod_1222346110578_21.doc @ 22258 

 

1.1.3 

Proper Use of the Industrial Switches 

The device is designed for the IP30 protection class. It is protected against the 
insertion of solid items and solid impurities up to 2.5 mm in diameter, but not 
against water penetration. Unless otherwise specified, the device must not be 
operated in wet and dusty environments. 

Pos: 2.7 /Alle Serien (Allgemeine Module)/Wichtige Erläuterungen/Technischer Zustand der Geräte @ 3\mod_1221060446109_21.doc @ 21723 

 

1.1.4 

Technical Condition of Specified Devices 

The components to be supplied Ex Works, are equipped with hardware and 
software configurations, which meet the individual application requirements. 
Changes in hardware, software and firmware are permitted exclusively within the 
framework of the various alternatives that are documented in the specific manuals. 
WAGO Kontakttechnik GmbH & Co. KG will be exempted from any liability in 
case of changes in hardware or software as well as to non-compliant usage of 
components. 

Please send your request for modified and new hardware or software configu-
rations directly to WAGO Kontakttechnik GmbH & Co. KG. 

Pos: 2.8 /Serie 852 (Ethernet-Zubehör)/Wichtige Erläuterungen/Normen und Richtlinien @ 3\mod_1222346239453_21.doc @ 22261 

 

Summary of Contents for 852-111

Page 1: ...Manual WAGO ETHERNET Accessories 852 5 Port 100BASE TX Industrial Eco Switch 852 111 Assembly Installation and Handling Version 1 0 0...

Page 2: ...hnical Support Phone 49 0 571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However a...

Page 3: ...trial Switches 6 1 3 Symbols 7 1 4 Safety Information 9 1 5 Font Conventions 10 1 6 Number Notation 10 2 General 11 2 1 Package Contents 11 2 2 Industrial Ethernet Technology 11 2 3 Switching Technolo...

Page 4: ...ts WAGO ETHERNET Accessories 852 852 111 5 Port 100BASE TX Industrial Eco Switch Manual Version 1 0 0 List of Tables 25 Pos 1 4 Dokumentation allgemein Gliederungselemente Seitenwechsel 3 mod_12211080...

Page 5: ...n All sequences implemented on Series 852 devices may only be carried out by electrical specialists with sufficient knowledge in automation The specialists must be familiar with the current norms and...

Page 6: ...machine e g BGV A 3 Electrical Installations and Equipment Emergency stop functions and equipment must not be deactivated or otherwise made ineffective See relevant standards e g DIN EN 418 Your insta...

Page 7: ...death or serious injury WARNING Personal Injury Indicates a moderate risk potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Personal Injury Indicates...

Page 8: ...dustrial Eco Switch Manual Version 1 0 0 Information Additional Information Refers to additional information which is not an integral part of this documentation e g the Internet Pos 2 11 Dokumentation...

Page 9: ...aerosols silicones triglycerides found in some hand creams If it cannot be determined that these materials appear in the component environment then the components must be installed in an enclosure th...

Page 10: ...Start of measurement range Value Input or selective values are marked in inverted commas e g Enter the value 4 mA under Start of measurement range Button Pushbuttons in dialog boxes are marked with b...

Page 11: ...ransmitting among connected Ethernet or Fast Ethernet LAN segments Switching is a cost effective way of increasing the total network capacity available to users on a local area network A switch increa...

Page 12: ...itung Port Geschwindigkeit und Duplex Modus 3 mod_1222427724921_21 doc 22294 2 6 Port Speed Duplex Mode After a cable is plugged into a specific port the system uses auto negotiation to determine the...

Page 13: ...buffer is effectively allocated for each port while controlling the data flow between the transmit and receive nodes to guarantee against all possible packet loss Pos 6 3 Serie 852 Ethernet Zubeh r Ge...

Page 14: ...Module berschriften f r alle Serien Ansicht berschrift 2 4 mod_1240984217343_21 doc 31958 3 1 View Pos 6 6 Serie 852 Ethernet Zubeh r Ger tebeschreibung Ansichten 852 111 4 mod_1236850581515_21 doc 2...

Page 15: ...le connector for power input PWR RPS and alarm dry contact 2 Primary power LED 3 Grounding Scew Pos 6 7 Alle Serien Allgemeine Module berschriften f r alle Serien Anschl sse berschrift 2 4 mod_1240984...

Page 16: ...onnector shows the following pin assignment Table 3 Power Input PWR Name Designation PWR Primary DC input PWR Primary DC input Figure 4 Power input GND Ground NOTICE Warning of damage to equipment by...

Page 17: ...f 3 3 2 Port LED s Table 5 Port LED s LED Desig nation Status Description Green Port operating at 100 Mps 1 LED for each port 100 TX port 100 Mbps LED Off Port operating at below 100 Mps Green Illumin...

Page 18: ...commend considering the following rules Install the Industrial Switch at an appropriate place See chapter Technical Data for the acceptable temperature and humidity operating ranges Fix the provided b...

Page 19: ...E TX Industrial Eco Switch Manual Version 1 0 0 Figure 8 Assembly on carrier rail 1 Figure 9 Assembly on carrier rail 2 4 3 Screw fixing The Industrial Eco Switch can be mounted in the boreholes on th...

Page 20: ...ion from and adequate ventilation around the Industrial Switch Do not place heavy objects on the Industrial Switch The carrier rail must optimally support the EMC measures integrated into the system a...

Page 21: ...tact pins and can be inserted and removed easily by hand to connect to the three pin terminal block male contacts located on the body of the Switch 1 Check the front panel LEDs as the device is powere...

Page 22: ...ach port 1 x Link Activity LNK ACT green 1 x Speed 100 Mbps green Supply voltage DC 18 V 30 V Energy consumption max 3 W Operating temperature 0 C 60 C Storage temperature 20 C 80 C Relative air humid...

Page 23: ...00Base TX The pin assignments are as follows Table 7 RJ 45 Cables Pin Pair Colours 1 TD Pair 2 White Orange 2 TD Pair 2 Orange White 3 RX Pair 3 White Green 4 N A Pair 1 Blue White 5 N A Pair 1 White...

Page 24: ...res Figure 1 Front view of Industrial Eco Switch 14 Figure 2 Top view of Industrial Eco Switch 15 Figure 3 10 100BASE TX 15 Figure 4 Power input 16 Figure 5 Unit LED 17 Figure 6 Port LEDs 17 Figure 7...

Page 25: ...ntation allgemein Verzeichnisse Tabellenverzeichnis berschrift 1 3 mod_1219222958703_21 doc 21084 List of Tables Table 1 Font Conventions 10 Table 2 Number Notation 10 Table 3 Power Input PWR 16 Table...

Page 26: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 49 5 71 8 87 0 Fax 49 5 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Reviews: