9970-0966
s08520000_00000004 V1.0.0 © 2018
WAGO Kontakttechnik GmbH & Co. KG
Hansastr. 27
D-32423 Minden
www.wago.com
En
Operating and Assembly instructions
Please keep!
Subject to design changes
Support: Phone: +49 (0) 571/8 87 - 5 55 / Fax: +49 (0) 571/8 87 - 85 55
Mail: support@wago.com
Industrial ETHERNET Switch
Industrial Switch
852-1411
1 Safety Information
Do not work when devices are energized!
High voltage can cause electric shock or burns.
Switch off all power to the device prior to performing any installation, repair or main
-
tenance work.
Live parts are likely to be touched!
The party setting up the device is responsible for providing appropriate touch guards.
The installation regulations must be observed for each individual application.
Laser radiation warning!
Do not stare into openings of the connections when no cable is connected, so as not
to expose the radiation. It can emit invisible radiation. It concerns here a laser class 1
according EN 60825-1.
i
Only valid in conjunction with the device‘s manual!
These instructions are only applicable in conjunction with the device‘s manual!
This manual is available on the Internet at www.wago.com/
<Item No>
.
In addition, please observe the information provided on the device’s housing.
Please especially observe the following:
• The device described in these instructions shall only be installed by a qualified electrician
according to both EN 50110-1/-2 and IEC 60364.
• Before startup, check the device for any damage that may have occurred during shipping. The
device shall not be put into operation in the event of mechanical damage.
• Only install this device in closed electrical service locations in accordance with EN 50178.
• Only install this device in dry indoor rooms.
• Do not install the devices on or in the vicinity of easily flammable materials.
• Ensure sufficient cooling of the device.
• Use the device exclusively on LANs. Never connect this device to telecommunications net
-
works such as analog or ISDN telephone systems.
The device must be used exclusively in accordance with these notes and the complete instructions
for use. Any other use can compromise safety and will render the warranty or guarantee null and void.
WAGO Kontakttechnik GmbH & Co. KG is not liable for damage caused by improper use.
2 Technical Data
Table 1: Device
852-1411
Dimensions (mm) W × H × D
50 × 120 × 160
Weight
800 g
Table 2: Connection
Port
Assignment acc. to
ETHERNET port copper RJ-45
5
10/100/1000BASE-T + PoE
ETHERNET port copper RJ-45
8
10/100/1000BASE-T
Table 3: Electrical Data
Supply voltage
24 … 57 VDC
Energy consumption max.
13 W; 133 W with 4 PoE
Table 4: Wiring
Connection technology
Push-in CAGE CLAMP®
Solid “s”
0.2 … 2.5 mm² / AWG 24 … 12
Fine-stranded “f-st”
0.2 … 2.5 mm² / AWG 24 … 12
Strip length
10 … 11 mm / 0.39 … 0.43 in
Table 5: Environmental Conditions
Surrounding air temperature (operation)
−40 … +70 °C
Surrounding air temperature (storage)
−40 … +80 °C
Relative humidity max.
95 % (without condensation)
3 View
Table 4: View
1
2
3
4
5
6
7
8
Pos. Assignment
1
Grounding screw
3
2
Connection supply voltage
PWR
3
Status LED supply voltage PWR
4
Status LED supply voltage Power over Ethernet
PoE
(1 LED for each port)
5
Connection RJ-45
(10/100/1000BASE-T + PoE)
6
Status LED T-Port-1000-
Mbps
(1 LED for each port)
7
Status LED T-Port LNK/ACT
(1 LED for each port)
8
Connection RJ-45
(10/100/1000BASE-T)
4 Mounting
Avoid electrostatic discharge!
The devices are equipped with electronic components that you may destroy by
electrostatic discharge when you touch. Please observe the safety precautions against
electrostatic discharge in accordance with EN 61340-5-1/-3
.
Pay attention while hand
-
ling the devices to good grounding of the environment (persons, job and packing).
4.1 Mounting
Mount the device vertically (power connection up).
Use of other mounting positions is at the user’s own risk.
Install the device in accordance to EN 60715 by snapping it onto DIN-rail.
1. Place the device with its DIN-rail guide on the top edge of the DIN-rail.
2. Press the device onto the DIN-rail and lock the device into place.
4.2 Removal
1. Push the device downwards to detach it.
2. Tilt the device forwards and unhook it from the DIN-rail.
5 Connection
5.1 Female Connector
The female connector serves to connect the power supply (PWR).
The following conductors can be inserted directly without tools:
• fine-stranded conductors with insulated ferrule, all cross sections
• fine-stranded conductors with uninsulated ferrule, cross section > 0.25 mm²/AWG 22
• solid conductors, cross section > 0.25 mm²/AWG 24
5.2 Communication
Close unused ports with the rubber covers included with the delivery.
6 LEDs und Error Signaling
The LEDs (green), which are visible on the front, indicate the following states:
• LED PWR (3) is illuminated in green:
use of the primary power supply
• LED PoE (4) is illuminated i green:
PoE power is present.
• LED 1000 (6) is illuminated in green:
1000 Mbps connection in operation
• LED LNK/ACT (7) is illuminated in green: connections linked
• LED LNK/ACT (8) flashes green:
data traffic via connection