68
Function Description
WAGO-I/O-SYSTEM 750
750-306 DeviceNet
TM
Fieldbus Coupler
Manual
Version 2.0.0
7.3.3
Addressing
7.3.3.1
Fieldbus-Specific Addressing
After turning on the power supply, the assembly object combines data from the
process image. As soon as a connection is established, a DeviceNet
TM
master
(scanner) can address the data with “class”, “instance” and “Attribute” and then
access it or read and/or write via I/O connections.
Data mapping depends on the assembly instance selected or on application-
specific determination with the dynamic assembly.
Additional Information
The assembly instances for static assembly are described in the section “Fieldbus
Communication” > … > “Assembly Instances.”
Additional Information
For the number of input and output bits or bytes of the individual I/O modules,
please refer to their corresponding descriptions.
Figure 39: Fieldbus-Specific Data Exchange