WAGO-I/O-SYSTEM 750
Fieldbus Communication 107
750-306 DeviceNet
TM
Fieldbus Coupler
Manual
Version 2.0.0
Table 76: Instance 4
Attributes
ID
Utilization
in Device
Access
Rights
Name
Data Type Description
14
required
get/set
produced_
connection_
path
Array of
USINT
Specifies application objects,
whose data are generated in this
“connection object”
15
required
get
consumed_
connection_
path_length
UINT
Number of bytes in
“consumed_connection_path”
attribute
16
required
get
consumed_
connection_
path
Array of
USINT
Specifies application objects,
whose data are received by this
“connection object”
17
required
get/set
production_
inhibit_time
USINT
Defines the minimum time
between data transmission
Services
Table 77: Service
Service
Code
Service Name
Description
0x0E
Get_Attribute_Single
Returns the content of a specific attribute
0x10
Set_Attribute_Single
Modifies the content of a specific attribute
0x05
Reset
Invokes the reset service for the device
The instances are unavailable when the connection is in “non-existent” mode.
I/O Connection Object State
Figure 47: I/O Connection Object State