28
•
Fieldbus coupler 750-342
Data exchange
Modular I/O System
ETHERNET TCP/IP
The input bytes D0 and D1 form the 16 bit reading of counter 1 and the input
bytes D2 and D3 form the 16 bit reading of counter 2.
When setting the counter, the load value of counter 1 is transferred in the out-
put bytes D0 and D1. The load value of counter 2 is transferred respectively in
the output bytes D2 and D3.
3.1.4.3.3 750-511, /000-002 2-Channel Digital Pulsewidth module
This process data architecture holds true for the 2 Channel Pulsewidth modu-
les 750-511 and 750–511/000-002.
Item-No.:
Description:
750-511
2DO 24V DC 0.1A Pulsewidth
750-511/000-002
2DO 24V DC 0.1A Pulsewidth 100Hz
The process image of the 750-511 and 750-511/000-002 appears with 6 bytes
of input and 6 bytes of output data. Four words in the process image are occu-
pied with word-alignment .
Address
Bytes
Comment
Module
Offset
High
Low
0
C/S-0
Control / Status byte
1
D1-0
D0-0
Data bytes
Module 1 Channel 1:
750-511,
750-511/000-002
2
C/S-1
Control / Status byte
3
D1-1
D0-1
Data bytes
Module 1 Channel 2:
750-511,
750-511/000-002
4
User data
User data
Data bytes
Module 2:
Analog Module Channel 1
5
User data
User data
Data bytes
Module 2:
Analog Module Channel 2
...
...
...
...
...
3.1.4.3.4 750-630, /000-00X SSI encoder interface 24 Bit
This process data architecture holds true for the SSI encoder interface modules
750-630, 750-630/000-001 and 750–630/000-006.
Item-No.:
Description:
750-630
SSI encoder interface 24Bit, 125kHz Gray code, alternative Data
format
750-630/000-001
SSI encoder interface 24Bit, 125kHz Binary code, alternative
Data format
750-630/000-006
SSI encoder interface 24Bit, 250kHz Gray code, alternative Data
format