13
Plotter IP350
8. Troubleshooting
If your WAGO plotter is not functioning correctly, please check the following:
Device fails to switch on.
Check whether the mains plug and connecting plug are plugged in correctly. Check whether the
socket being used is functioning properly. Is the green light on the power supply illuminated? If
not, please replace the power supply.
IP 350 does not respond to data downloaded from PC.
Is the interface cable connected properly? Replace the data cable if necessary. Is the correct
interface on the PC being used?
No labelling is taking place even though a plotter pen has been inserted.
Check whether the plotter pen has dried out or if there is sufficient ink in the pen. Refill or replace
the pen if necessary.
Poor labelling quality, uneven line thickness, missing items.
The plotter pen nib may be soiled. Clean the nib carefully using a lint-free cloth dipped in special
cleaning fluid. Replace the plotter pen if necessary.
Summary of Contents for IP 350
Page 1: ...Manual Plotter IP 350...