32
Function Description
WAGO-I/O-SYSTEM 750
750-657 IO-Link Master
Manual
Version 1.0.2, valid from FW/HW-Version 02/01
5.1
Parameter Model of the IO-Link Master
The parameters of the master are mapped to an IO-Link-specific data model.
A distinction is made between the following records:
•
Information and configuration data of the IO-Link master
(IOL-M Basic Configuration)
• Configurations
of
IO-Link ports 1 to 4
(IOL-M_Port Configuration 1..4)
•
Device identification of the IO-Link master
(I&M)
and attached devices
(I&M 0..4)
•
Information about the IO-Link master itself
(IOL-M Directory)
This information is read only.
•
Records of the attached IO-Link devices
(ISDU)
according to the IO-Link
specification.
The IO-Link-specific records are described in detail in the appendix, section "IO-
Link Master tables". More information about the "Indexed Service Data Unit"
(ISDU) is available in the section "Parameter Access via ISDU".
Figure 10: Parameter Model of the IO-Link Master
Pos: 68 /Dokumentation allgemein/Gliederungselemente/---Seitenwechsel--- @ 3\mod_1221108045078_0.doc @ 21810 @ @ 1
63
0
Register
IOL-M_Port Configuration 1..4
IOL-M Basic Configuration
I&M 0..4
ISDU
IOL-M Directory
IO-Link specific records
.
.
.
Port 1
Port 2
Port 3
Port 4
IO-Link Device