Table 25: Setting the CONNECT result code format and call monitoring
ATX
Setting the CONNECT result code format and call monitoring
Effective command
Command
ATX[<value>]
Response OK
Parameter <value>:
0: CONNECT
is
reported,
dial tone and busy tone-
detection is turned off <default setting>
1: CONNECT<text>
is
reported, dial tone and
busy done detection is turned off
2: like
1
3: like
1
4: like
1
Note
The term "tones" originates from the world of analog telephones.
The status "No dial tone" normally does not occur if the device is
logged into the GSM network. A busy signal is passed.
Table 26: Setting the DCD function
AT&C
Setting the DCD function
Effective command
Command
AT&C[<value>]
Response OK
Parameter <value>:
0: DCD signal is always on.
1: DCD signal is on during an existing connection
<default
setting>.
Note -
Table 27: Setting the DTR function
AT&D
Setting the DTR function
Effective command
Command
AT&D[<value>]
Response OK
Parameter <value>:
0: Device ignors DTR signal of the connected
equipment. <default setting>
2: ON>OFF of the DTR signal: Connection release and
switch to command phase. If DTR = OFF,
automatic call acceptance disabled.
Note -