WAGO WINSTA® 770
Device Description
17
770-629/130-000 WINSTA® Sunblind Box 4 Channel
Manual
Version 1.1.1, valid from HW/FW version XXXX0201XX
3.3.4
Local Push-Buttons
The local operating push buttons are connected to the push button inputs ("S1" to
"S4") with the corresponding plug connectors. This is safety extra-low voltage.
The installation of these lines must be carried out in SELV.
Table 6: Local push button connection
Connection
Designation Function
1 Down
2
12 V DC
1
2
3
1
2
3
WAGO
734-103 (Buchse)
734-603 (Gehäuse)
WAGO
734-103 (Buchse)
734-603 (Gehäuse)
Figure 7: Local push button connection
3 Up
3.3.5
Bus/Central Connection
Do not use unused connections!
Depending on the operating mode set, some connections are not connected (N.C.).
These connections cannot be used!
Usage can cause damage to or malfunction of the device!
The type of activation of the box can be selected with the help of an IDC
connector/jumper. At the factory, bus operation (activation via RS485 signal) is
pre-set. Alternatively, by changing the jumper, it is possible to select central
operation (activation via 24V DC control signal). The setting of the jumper is
described in the chapter "Putting into operation > Setting bus or central
operation."
In
bus operation
, a WAGO-I/O controller can be used on a bus segment to
connect up to 16 participants. These can be grouped and activated at will. The bus
connection is made using the four-pole plug ("Bus/central") and the plug
assignment "Bus."
With the help of a
24V DC control signal
, it is possible to move all of the
connected shades into the upper or lower end position. This way, the sunblind box
can be operated with a weather station, timer or a central switch. Central operation
is also connected using the four-pole plug with the designation "Bus/Central,"
however with the plug assignment "Central" and previous re-plugging of the
jumper.