WAGO WINSTA® 770
Connect Devices
31
770-629/130-000 WINSTA® Sunblind Box 4 Channel
Manual
Version 1.1.1, valid from HW/FW version XXXX0201XX
6.1.2
Bus Connection (Bus Operation)
On principle, the configuration of a bus activation using RS485 should take place
according to the following scheme.
B
120
W
L / N / PE
A
120
W
Bus Connection
Central Control
Figure 13: Wiring of the Winsta sunblind boxes in a bus system
Don't forget the bus end module!
The bus must be connected at the beginning and end to a 120
Ω
resistor!
Operation via bus signal/RS485
The following module is required to operate via bus signal/RS 485 and WAGO
I/O-System: WAGO I/O adjustable RS485 module 750-653/003-000
Pos: 55 /Dokumentation allgemein/Gliederungselemente/---Seitenwechsel--- @ 3\mod_1221108045078_0.doc @ 21810 @ @ 1