7.4.3
Grouping
Set the grouping with the switches 1, 2, and 3 of the DIP module 2.
The drives are thus assigned via the plug connectors to the selected groups and
local push buttons.
7.4.3.1
A Group: Moving Motors 1 to 4 Simultaneously
In order to form just one group in which all connected motors move at the same
time, make the following settings:
Table 17: One group, motors 1 to 4 move simultaneously
Assignment of motors - local push buttons
Motor
1 2 3 4
ON
DIP
1 2 3
4 5 6
ON
DIP
1 2 3
4 5 6
Figure 20: One group, motors 1
to 4 move simultaneously
Push
button
S1 S1 S1 S1
7.4.3.2
Two Groups: Moving Motors 1 and 2 and Motors 3 and 4
Simultaneously
To form two groups, Group A in which motors 1 and 2 and Group B in which
motors 3 and 4 move together, make the following settings:
Table 18: Two groups: motors 1 and 2 and motors 3 and 4 move simultaneously
Assignment of motors - local push buttons
Motor
1 2 3 4
ON
DIP
1 2 3
4 5 6
ON
DIP
2 3
4 5 6
1
Figure 21: Two groups: motors 1
and 2 and motors 3 and 4 move
simultaneously
Push
button
S1 S1 S3 S3
7.4.3.3
Two Groups: Moving Motors 1, 2, and 3 Simultaneously, Motor 4
Moves Individually
In order to combine the motors 1, 2, and 3 into group A while motor 4 moves
individually, make the following settings:
Table 19: Two groups: motors 1, 2, and 3 move simultaneously, motor 4 moves individually
Assignment of motors - local push buttons
Motor
1 2 3 4
ON
DIP
1 2 3
4 5 6
ON
DIP
1 2 3
4 5 6
Figure 22: Two groups: motors 1,
2, and 3 move simultaneously,
motor 4 moves individually
Push
button
S1 S1 S1 S4