Page 32
User Guide
Wahl DHS520
1)
Check the battery status, ensure that there is sufficient battery life
remaining
2)
Assess the intended target. If the target temperature is likely to be
above 1200°C/2192°F, fit the dark window (supplied as a standard
accessory)
3)
Go into
Menu Mode
, open the
Trigger Mode
menu and select
Classic
Mode
4)
Enter the ‘Emissivity’ value for the material under observation (0.35)
If the window compensation factor of the viewing window/port is known:
5)
Set
Window Compensation
to
On
.
6)
Enter the known compensation factor (0.920)
If the ‘Window Compensation’ factor of the viewing window/port is not known:
7)
Take and record a reading with the thermometer of a known temperature
value, with the emissivity set to correspond and the
Window
Compensation
factor set to default (i.e. blackbody heat
source, emissivity set to 1.00 and
Window Compensation
set to
1.000).
8)
Place a spare viewing window/port between the thermometer and the
blackbody heat source and take a new temperature reading.
9)
Enter the
Window Compensation
>
On
sub-menu and amend the
Window Compensation factor value with the
and
keys until the
display temperature reads the same as the recorded value taken from
the known value source. You must now use this
Window
Compensation
value, as it is correct for the chosen viewing window/
port material (0.920)
10)
Ensure that the
Alarms
function is set to
Off
.
11)
Ensure the
Bluetooth
option is set to
Off
(
Wahl DHS520B
variants only)
12)
Select the
Continuous
temperature measurement option.
13)
Aim the thermometer through the viewing window/port at the target and
focus the reticule onto the area under observation. Check that the
reticule is fully filled by the target, re-position if necessary
14)
Press the trigger to start measurement. The main display and eyepiece
display are updated with the reading.
15)
Release the trigger to stop measurement and freeze the last recorded
value on the main display.
Summary of Contents for Heat Spy DHS520
Page 2: ......
Page 3: ......
Page 9: ......
Page 12: ......
Page 14: ...Page 2 Wahl DHS520 User Manual Fig 1 Wahl DHS520 520B portable infrared thermometer ...
Page 21: ......
Page 35: ...User Manual Wahl DHS520 Page 22 Blank ...
Page 37: ......
Page 38: ...Wahl DHS520 Page 24 Blank UserGuide ...
Page 39: ...User Manual Wahl DHS520 ...
Page 40: ......
Page 45: ......
Page 51: ......
Page 59: ...Page 43 User Manual Wahl DHS520 ...