805.245.005
Date: January 10, 2017
6
Emergency stop switch (Optional)
The Winch can be configured with an emergency stop
By default the emergency stop is NOT enabled!
If the emergency stop switch is activated (pin 1 and pin 4 are disconnected) the red ERROR
LED will light.
The emergency stop switch is connected to the male 4 pole XLR connector.
Pin 1 and Pin 4 should be powered with 12-15 volt DC to enable the running of the motor
Pin out:
Pin 1 = GND
Pin 2 = NC
Pin 3 = NC
Pin 4 = 12 – 15 volt DC
Ready to use
When the Rolldown has been
connected to power, DMX, and an
emergency stop switch, it is ready
for use, and can be controlled from
the lighting desk.
Enable Emergency stop
To enable to emergency stop 2 steps are required. First in the menu change E STOP to ON.
Secondly inside the unit there is an orange wire that needs to be set correctly for operation
with/without emergency stop.
Emergency stop disabled
Emergency stop enabled
When the emergency stop is enabled and the little piece of orange wire is not connected it is
recommended that it is secured in some way so it does not hit anything. Some electrical tape will be