255.805.001
30
Date: 2021-03-12
LED Functions
DMX LED
The DMX lamp will be steady green when receiving a DMX signal.
The DMX lamp will flash green if no DMX signal is present.
Error LED
The error LED will light red if there is an error or if the emergency stop is active.
Reset error is done by setting DMX channel 4 to 0%.
When the Error LED lights red, there will also be an error description in the display.
Error and error codes
Error
Possible solution
AC Motor Controller will not
start, display shows nothing.
Check if the AC Motor Controller is connected to mains power incl. Null, and
Earth.
The AC Motor Controller will
not start, DMX lamp is
blinking.
Check DMX connection.
The motor will not run, DMX
LED is steady green.
Check limit switch inputs are connected.
The motor stops running after
some time.
The surrounding temperature has made the AC Motor Controller to hot,
above 70 °C (158 °F), so it has turned off the motor output. Reactivate the
output by toggling the emergency stop, or by setting DMX channel 4 to 0.
When an error occurs, the control system shuts down the connected motor and issues a
corresponding error code. This can be queried and used to determine the cause of the error.
Error can be reset by toggling the emergency stop, or by setting DMX channel 4 to 0.