15
246.805.201
Date: 2017-09-26
Emergency stop switch (Optional)
The Winch can be configured with an emergency stop
Warning! By default the emergency stop is NOT enabled!
If the emergency stop switch is activated (pin 1 and pin 4 are disconnected) the red
ERROR
LED will light.
The emergency stop switch is connected to the male 4 pole XLR connector.
Pin 1 and Pin 4 should be powered with 12-15 volt DC to enable the running of the
motor
Pin out:
Pin 1 = GND
Pin 2 = NC
Pin 3 = NC
Pin 4 = 12 – 15 volt DC
Ready to use
When the Winch 50 has been connected
to
power, DMX, and an emergency stop
switch, it is ready for use, and can be
controlled from the lighting desk.
Enable Emergency stop
To enable to emergency stop 2 steps are required.
The first step is to set emergency stop in the software to ON.
Access the menu, and find the menu E STOP:
Set E STOP to ON
Summary of Contents for Winch 50 Double