background image

                                                                                                                                                        DeltaFire 500 User’s Guide

311-090001

 © 1999 WaiLAN Communications, Inc.

Page 15

SNMP Features Supported

The main features of the DeltaFire devices’ SNMP support are as follows:

• 

Supports standard MIB-II MIBs, as defined in RFC 1213.

• 

Supports two WaiLAN private MIBs: wailan.mib and df500.mib.

Summary of Contents for DeltaFire 500

Page 1: ...DeltaFireTM 500 User s Guide ...

Page 2: ...nications Inc Address WaiLAN Communications Inc 2032 Bering Drive San Jose CA 95131 Phone 408 452 8081 Fax 408 452 8381 URL www wailan com Notice AGATE and DeltaFire are trademarks of WaiLAN Communications Inc All other company or product names mentioned are the property of their respective owners All rights reserved ...

Page 3: ...owing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help WARNING In order to meet FCC emission limits and to prevent interference to nearby radio and television receptio...

Page 4: ...ort Configuration 9 IP Range Table 10 Static Routing Table 10 SNMP Configuration 11 Change Password 12 Reset 12 Software Upgrade 12 SNMP Support 13 TROUBLESHOOTING 18 Table 1 Troubleshooting Procedures 18 APPENDIX A TECHNICAL SPECIFICATIONS 19 Table 2 Technical Specifications 19 Table 3 MSDSL Line Card Rate at Different Cable Lengths 19 Table 4 RADSL Line Card Rate at Different Cable Lengths 20 AP...

Page 5: ...is with a dual redundant load balancing hot swappable plug in power supply The Main Controller Board occupies the bottom slot while the remaining four slots allow hot swappable plug in line cards for different line encoding technologies such as RADSL or MSDSL The line card plug in cards can be mixed Features Layer 2 access switch for 24 xDSL ports plus Ethernet port transparent to upper layer prot...

Page 6: ...iber Optic I F optional plug in module 5 Line Card Standard 50 pin Telco connector optional 6 port RJ 11 harmonica LED Indicators Power Supply Power OK Green LED on during normal operation Control Card PWR Red LED on when power failure occurs SYS Green LED on when system failure occurs RUN Yellow LED blinks with normal operation 100M Yellow LED on when 100Base T plugged into LAN port RX TX Yellow ...

Page 7: ...bridge taps on it For example Pacific Bell s Local Area Data Channels LADC use USOC code to specify a 2 wire dry line as T6E2D NOTE The term non loaded or non loaded coils means no passive lowpass filter for voice spectrum on the line With a lowpass filter the loop is used for voice signal only the high frequency spectrum of signals above 4Khz will be filtered out and the loop cannot be used for x...

Page 8: ...ddress is assigned to the DeltaFire device users can telnet to the DeltaFire device for system configuration An appropriate IP address for the user s network must be configured by a console terminal before the telnet command can be used CONFIGURATIONS MONITORING Main Menu After making a connection to the DeltaFire device press Enter a few times to see the screen below Select the desired function b...

Page 9: ...e changed to fit into the user s network in which the DeltaFire will be deployed The Microprocessor line shows the CPU type on the Controller Board and the serial number of the Board in on the following line The tenth and eleventh lines display the Hardware Revision and Software Version You should check the WaiLAN Web site www wailan com to see if the software is the latest version if not you shou...

Page 10: ...pe in the new name in the appropriate VLAN No column and press Ctrl s and Enter To change the configuration of the VLAN the user must press the Space Bar on the appropriate parts to add or remove an X and then press Ctrl s and Enter to save Note No changes will be saved if the user does not press Ctrl s and then Enter VLAN Configuration Slot1 Slot2 Slot3 Slot4 No VLAN Name ETH 1 2 3 4 5 6 1 2 3 4 ...

Page 11: ...lar port belongs to this can not be changed here Note All changes require that the user press Ctrl s and then Enter Port Configuration Speed InBw OutBw Slot Port Type Port Name kbps AdmSta OpSta kbps kbps 1 1 DFLC700 0 ON DOWN 0 0 1 2 DFLC700 0 ON DOWN 0 0 1 3 DFLC700 4480 ON UP 0 0 1 4 DFLC700 0 ON DOWN 0 0 1 5 DFLC700 0 ON DOWN 0 0 1 6 DFLC700 0 ON DOWN 0 0 2 1 DFLC200 0 ON DOWN 0 0 2 2 DFLC200 ...

Page 12: ...dditional information on SNMP refer to the SNMP Support section Note All changes require that the user press Ctrl s and then Enter Static Routing Table Slot Port Network ID Subnet Mask Next Hop Metric 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0...

Page 13: ...ement software such as HP s OpenView and Castle Rock s SNMPc to manage and monitor the DeltaFire devices The section below describes how to configure your DeltaFire devices to support SNMP Note This document assumes you know how to use SNMP network management software and how to configure hosts and set up communities under SNMP For information about SNMP you can consult some reference information ...

Page 14: ...on in each MIB file s header to see if you have the latest MIB files If new MIBs are available you should download them from the WaiLAN Web site and install the new MIBs in your SNMP management software After you install the MIB files in your SNMP management software make sure you re compile the MIB files using your SNMP management software Make sure you compile the wailan mib first then the df500...

Page 15: ...resses for the IP fields text for the other fields 5 Press the arrow keys to move the cursor up down left or right to the next field you want to edit 6 Press the Esc key when you are finished editing information in the current table Deleting a Row To delete a row of information 1 Position the cursor in the row you want to delete 2 Type Ctrl d A prompt appears to confirm you want to proceed Press t...

Page 16: ...e to access the device in the SNMP Management Hosts table Specifying Who Can Access the Device You can specify the hosts on the network that will be allowed to access the device You use the SNMP Management Hosts table to do this This feature adds an additional level of security to the device Note If the Limit Access to SNMP Hosts option is turned on only the hosts you specify will be allowed to ac...

Page 17: ...99 WaiLAN Communications Inc Page 15 SNMP Features Supported The main features of the DeltaFire devices SNMP support are as follows Supports standard MIB II MIBs as defined in RFC 1213 Supports two WaiLAN private MIBs wailan mib and df500 mib ...

Page 18: ...ical Support Information Table 1 Troubleshooting Procedures SYMPTOM PROBLEM SOLUTION No LED display AC cord unplugged Check connections Green light all LED steady ON System Down Try Reset by unplugging plugging the power jack No Response from LAN port Possibly wrong 10Base T cable being used Use straight 10Base T cable to hub or switch Use crossed 10Base T cable to PC or Router Can t Telnet Ping t...

Page 19: ...1 5 0 75 Amp 48 VDC option Environmental Humidity Operating Temp Storage Temp Up to 95 non condensing 32 122 F 4 158 F Physical Dimensions H 5 1 4 x W 17 1 4 x D 14 Table 3 MSDSL Line Card Rate at Different Cable Lengths When the DFLC200 line card is connected to AGATE 200 the data rate is automatically adapted according to the configuration setting from the AGATE 200 NOTE The reach distance can c...

Page 20: ...544 408 272 9 3 2 8 10 1 3 1 11 0 3 4 12 0 3 7 11 9 3 6 12 7 3 9 14 0 4 3 15 2 4 6 Config NO 2 5120 4480 3200 1920 1088 952 816 680 544 408 272 10 3 3 1 11 1 3 4 12 1 3 7 13 4 4 1 13 1 4 0 14 2 4 3 15 5 4 7 16 9 5 2 Config NO 3 2560 2240 1920 1600 1280 960 640 1088 952 816 680 544 408 272 11 8 3 6 12 9 3 9 13 5 4 1 14 1 4 3 14 7 4 5 15 1 4 6 15 8 4 8 15 1 4 6 16 5 5 0 17 2 5 2 18 2 5 5 19 1 5 8 19...

Page 21: ... 1 Tip 2 N A 27 N A 3 N A 28 N A 4 Port 2 Ring 29 Port 2 Tip 5 N A 30 N A 6 N A 31 N A 7 Port 3 Ring 32 Port 3 Tip 8 N A 33 N A 9 N A 34 N A 10 Port 4 Ring 35 Port 4 Tip 11 N A 36 N A 12 N A 37 N A 13 Port 5 Ring 38 Port 5 Tip 14 N A 39 N A 15 N A 40 N A 16 Port 6 Ring 41 Port 6 Tip 17 N A 42 N A 18 N A 43 N A 19 N A 44 N A 20 N A 45 N A 21 N A 46 N A 22 N A 47 N A 23 N A 48 N A 24 N A 49 N A 25 N...

Page 22: ...A N A 5 Signal Common Ground 6 N A N A 7 N A N A 8 N A N A 9 N A N A Table 7 10 100Base T Port RJ 45 Pin Layout RJ 45 PIN Direction PIN Assignment 1 OUTPUT TXD 2 OUTPUT TXD 3 INPUT RXD 4 N A N A 5 N A N A 6 INPUT RXD 7 N A N A 8 N A N A NOTE You must use straight Ethernet cable to connect to an Ethernet hub switch etc To connect to a PC router etc you must use a cross over Ethernet cable ...

Page 23: ...________________ Line Circuit Number ________________________ Copper pair s length ________ Kft Km Impedance ___________ Ω The Ethernet Address assigned _____________________ IP Address assigned ______________________________ Unit 4 Unit 4 Location ___________________________________ System Install Date ______________________________ The firmware version is ____________________________ The console...

Page 24: ...___ Kft Km Impedance ___________ Ω The Ethernet Address assigned _____________________ IP Address assigned ______________________________ Unit 13 Unit 13 Location __________________________________ System Install Date ______________________________ The firmware version is ____________________________ The console management password is ________________ Line Circuit Number ________________________ C...

Page 25: ...l Date ______________________________ The firmware version is ____________________________ The console management password is ________________ Line Circuit Number ________________________ Copper pair s length ________ Kft Km Impedance ___________ Ω The Ethernet Address assigned _____________________ IP Address assigned ______________________________ Unit 22 Unit 22 Location _______________________...

Page 26: ...Technical Support Information WaiLAN Communications Inc 2032 Bering Drive San Jose CA 95131 Technical Support Phone 408 452 8081 FAX 408 452 8381 Email support wailan com Response within one working day URL www wailan com for additional information diagrams and firmware updates ...

Page 27: ...311 090001 1998 WaiLAN Communications Inc All Rights Reserved Printed in USA 15 00 ...

Reviews: