Summary of Contents for HYBRID WATER SYSTEM 15 g/h

Page 1: ...1 TRAITEMENT D EAU NATUREL POUR PISCINE ET SPA OWNER S MANUAL MANUEL UTILISATEUR...

Page 2: ...E COLISAGE P4 2 PRECAUTIONS TO BE TAKEN BEFORE INSTALLATION PR CAUTIONS PRENDRE AVANT INSTALLATION P5 3 INSTALLATION INSTRUCTIONS INSTRUCTIONS DE MONTAGE P6 4 HYBRID WATER SYSTEM POWER PACK HYBRID WAT...

Page 3: ...CELL HOUSING 4 O RING 5 CAP 6 REDUCING BUSHES x From 60mm to 50mm x From 60mm to 63mm 7 CELL SENSOR FLOW GAS 1 BOITIER LECTRIQUE 2 CELLULE 3 LOGEMENT DE CELLULE 4 JOINT 5 CULOT 6 R DUCTIONS x De 60mm...

Page 4: ...uctions Manual before beginning installation of this product S assurer que le produit est d branch avant de commencer l installation ou la maintenance Le non respect de ces dispositions peut entra ner...

Page 5: ...ust always be positioned above the cell 7 to function effectively 3 2 CELLULE D ELECTROLYSE Se r f rer au sch ma 3 1 Il est recommand d installer la cellule d lectrolyse dans un rayon de 1 5m sur un m...

Page 6: ...entilation est suffisante Le syst me d alimentation doit tre install sur un mur vertical dans un rayon de 1 5m de la cellule et au moins 1 m tre du sol Pour connecter la cellule il y a 3 connexions l...

Page 7: ...SIUM Le syst me H W S a t con u pour fonctionner avec un taux de Sel ou Magn sium optimum de 1 2 g l 1 5 g l La plage de concentration se situe entre 1 et 2 g l A la mise en service 2 g l sont n cess...

Page 8: ...me est en marche l affichage indiquera le taux de production de d sinfectant Par d faut l appareil est r gl sur 100 HYBRID WATER SYSTEM produit le d sinfectant issu du Sel ou du Magn sium et une eau...

Page 9: ...Regulation optional oraFreshIntelligencemodule A simple to use timer can be used to control the operating time of the HWS pump for the filtration system Une horloge de programmation peut tre ajout e...

Page 10: ...veau de d sinfectant lecteure chlore pastilles DPD 1 soit maintenu Pour une mesure prise pr s du skimmer le niveau d hydroxyde de Magn sium ou d hypochlorite de sodium lecture chlore doit tre au minim...

Page 11: ...hes are known to have a calcium problem and a Self Cleaning Chlorinator is an option to eliminate frequent cleaning of the chlorinator cell Note Chlorine or disinfectant is produced in both polarities...

Page 12: ...d on a low and regular no chemical chlorine production it is not unusual as you can have a visually perfect water to measure low or no chlorine level 9 4 PRODUCTION FAIBLE DE DESINFECTANT Se r f rer l...

Page 13: ...points suivants 1 POWER POINT NOT TURNED ON 2 FAULTY POWER POINT 3 TIME CLOCK SET INCORRECTLY 4 UNIT INCORRECTLY INSTALLED 5 POOR WATER CHEMISTRY SALT PH ETC 6 CELL NOT MAINTAINED 7 WATER FLOW TOO LO...

Page 14: ...ssance non prot g contre les l ments climatiques ou lectriques ou install dans un local technique avec une mauvaise ventilation D faut de maintenance de la cellule ou d bit d eau trop faible Cette gar...

Page 15: ...SEDFROM NOMDUREVENDEUR DATEOFPURCHASE DATED ACHAT MODEL MOD LE SERIALN N DES RIE BUYER INFORMATIONS INFORMATIONS ACHETEUR THIS SECTION MUST BE FILLED OUT ON PURCHASE TO VALIDATE WARRANTY CETTE SECTION...