Starting to use your safe

 

As soon as the safe has been delivered and correctly anchored, you can start operating 
the lock and using the safe. 
To do so, please keep to the following procedure: 
 

1.

 

Check that the rotary opening handle is 
in the 'closed' position. Do this by 
applying gentle pressure to move the 
rotary opening handle counterclockwise 
into the end position. 

 

 

2.

 

Carefully unscrew the flathead screw 
(positioned centrally under the input unit) 
out of the housing (2 mm Allen key). 

 
 
 
 

 

3.

 

Carefully pull the battery case 
downwards out of the input unit housing 
(six acoustic signals) and insert three 1.5 
V AA alkaline batteries (LR6), or 1.5 V AA 
lithium batteries (FR6) into the battery 
case. 
 
 
 
 

 

4.

 

Push the battery case carefully back up 
into the housing and screw it in tightly 
with the flathead screw (2 mm Allen key). 
The display shows: BATCASE OPEN. To 
delete this message again, enter the 
opening code and confirm it with the 
Enter key. 
 

 

 

5.

 

Enter the factory code (0-0-1-2-3-4-5-6) 
and confirm with the Enter key, then turn 
the rotary opening handle clockwise into 
the end position. 

 

 

6.

 

Open the door. A short acoustic signal 
(six beeps) every 30 seconds via the 

 

Pay attention to the polarity of the 
batteries! 

Summary of Contents for AXESSOR

Page 1: ...www tresore ch OPERATING INSTRUCTIONS SAFE LOCK AXESSOR Electronic safe lock for WA safes...

Page 2: ...the EN1143 1 standard A Swiss quality product with security tested by the VdS German Association of Indemnity Insurers Before starting to use your strongbox please read these instructions thoroughly...

Page 3: ...nals mean 2 Description of the keys 2 Description of display messages 2 Starting to use your safe 3 Operation 4 Opening the safe 4 Locking the safe 5 Reprogramming codes 5 Setting the time and date 6...

Page 4: ...e than the standard lock Operating controls WALDIS Eco and Business Input unit Rotary opening handle NOTE These operating instructions describe how to handle a safe in each case they show a version wi...

Page 5: ...pecialist dealer Description of the keys Pos 1 DEL key Delete Pos 2 MODE key Access to programming mode Pos 3 ENTER key Confirm input Pos 4 INF ESC key Lock information go back one menu level Pos 5 Ar...

Page 6: ...llen key 3 Carefully pull the battery case downwards out of the input unit housing six acoustic signals and insert three 1 5 V AA alkaline batteries LR6 or 1 5 V AA lithium batteries FR6 into the batt...

Page 7: ...e 2 Press any key to activate the input unit Enter the code and confirm it with the Enter key Within 5 seconds after the short acoustic signal six beeps you must turn the rotary opening handle clockwi...

Page 8: ...opening of the safe must be performed and it must be repaired or replaced at the owner s expense The certification lapses in case of a repair Procedure 1 Open the door with the current code 2 Leave t...

Page 9: ...open and the rotary opening handle in the open position press the Mode key the display shows PRG MOD 2 Input the existing master code confirm with the Enter key and the display will show TIME 3 Confir...

Page 10: ...key The display shows BATCASE OPEN To delete this message again enter the opening code and confirm it with the Enter key Malfunctions Battery If there is insufficient battery voltage the display show...

Page 11: ...y or any car registration numbers or phone numbers Don t use a code that you already use elsewhere How should a code be structured The code should not have a logical structure Use all the keys as far...

Reviews: