500.0024-A
14
Subject to technical changes
Terminal
Description
Capacity/comments
7 (OUT1+) / 8
(OUT1
–
)
Output 1
Standard: lock 1 open
Output voltage: 24 VAC
Power load at output:
0.4 A at 25°C
0.3 A at 50°C
ext.
OUTx
+
OUTx
–
9 (OUT2+) / 10
(OUT2
–
)
Output 2
Standard: all locks and
door bolts open
11 (OUT3+) / 12
(OUT3
–
)
Output 3
Standard: resistance
monitoring input
sabotaged
22 (OUT4+) / 23
(OUT4
–
)
Output 4
Standard: external
tamper input
24 (OUT5+) / 25
(OUT5
–
)
Output 5
Standard: threat alarm
impulse
35 (OUT6+) / 36
(OUT6
–
)
Output 6
Standard: threat alarm
with code
37 (OUT7+) / 38
(OUT7
–
)
Output 7
Standard: battery case
open
NO
I/O box