500.0023-A

 

Subject to technical changes

 

 

5.

 

Carefully re-insert the battery case and 
swivel it upwards into the housing of the 
input unit until the battery housing clicks 
into place. 
As soon as the input unit is supplied with 
power, the display shows one of these 
messages: 

"Battery case was open, 

battery inserted" or "Battery case was 
open, rechargeable battery pack 
inserted".

 

 

 

6.

 

To delete the battery message, you must 
first press the ENTER key and then enter 
the master code (MA1) or the battery 
code (11111111). The lock can then be 
used again in the normal way. 

 

7.

 

Press the ENTER key and the display will 
show the 

"Date, time saved" message.

 

 

8.

 

Press the ENTER key repeatedly, and the 
display will show the 

"Open menu" 

message; confirm this again with the 
ENTER key.

 

 

9.

 

The display 

shows the "Lock code" 

message to indicate that 

user code 1 

or 2 (11223310 or 11223320) must be 
entered.

 

If the code was entered 

correctly, the display shows the 

"Lock is 

opening" message, followed by "Lock 
is open, open the bolt". 

The rotary 

opening handle can only be moved 
clockwise after the second message. 

 
 
 
 

 

10.

 

Open the door (display shows 

"Released").

 

 
 
 
 
 

 

11.

 

Programme the new code as per section 
3.4. 

 

 

Summary of Contents for PAXOS ADVANCE

Page 1: ...www tresore ch OPERATING INSTRUCTIONS SAFE LOCK PAXOS ADVANCE Electronic safe lock for WA safes...

Page 2: ...the EN1143 1 standard A Swiss quality product with security tested by the VdS German Association of Indemnity Insurers Before starting to use your strongbox please read these instructions thoroughly...

Page 3: ...fe 6 3 3 Opening the safe under threat 6 3 4 Reprogramming codes 7 3 4 1 User code 01 OCa1 and user code 02 OCb1 7 3 4 2 Master code 1 8 3 5 Setting the date and time 8 3 6 Replacing the battery 9 Mal...

Page 4: ...u to use various additional functions which are not possible with the standard lock 1 1 Operating controls WALDIS Eco and Business Input unit Rotary opening handle NOTE These operating instructions de...

Page 5: ...l Pos 3 Arrow key up left Select the next menu item Select the next input value Pos 4 Arrow key down right Select the next menu item Select the next input value Pos 5 ENTER key Confirm inputs Call up...

Page 6: ...elease the battery case that is slotted into the input unit from below and swivel it downwards and outwards 3 The battery holder B is inserted in the battery case release it from the case and fit six...

Page 7: ...the battery code 11111111 The lock can then be used again in the normal way 7 Press the ENTER key and the display will show the Date time saved message 8 Press the ENTER key repeatedly and the display...

Page 8: ...ode message to indicate that factory code 1 or 2 11223310 or 11223320 must be entered If the code was entered correctly the display shows the Lock is opening message followed by Lock is open open the...

Page 9: ...alarm which cannot be heard at your location can be sent to the alarm centre when the code to open the safe is entered in the normal way To trigger the threat alarm the value of the last two digits o...

Page 10: ...axos Advance electronic high security lock is normally in Sleep mode power saving mode The lock is activated with the ENTER key 3 4 1 User code 01 OCa1 and user code 02 OCb1 NOTE It is essential to re...

Page 11: ...key confirm the Code functions menu that is shown on the display by pressing the ENTER key again 4 Use any arrow key to select 00 MA1 and confirm with the ENTER key the display shows Change 5 Confirm...

Page 12: ...the battery case release it from the case and fit six 1 5 V AA alkaline batteries LR6 E91 or AM3 into it As an option you can also insert a rechargeable battery pack A from Dorma Kaba in this case th...

Page 13: ...mentioned the battery for the lock must be replaced as quickly as possible section 3 6 The lock can be operated until the battery voltage drops below 6 5 volts No codes or settings are deleted when a...

Page 14: ...ff 5 1 Assignment of terminals on the I O box The I O box has 8 inputs and 8 outputs connections for the power supply and an RS232 interface NOTE The I O box functions are only available when the I O...

Page 15: ...on Connection with tamper monitoring switch factory configuration 3 IN2 4 GND Input 2 Standard bypass opening delay 5 IN3 6 GND Input 3 Standard interrupt lockout time 16 IN4 17 GND Input 4 Standard e...

Page 16: ...at 50 C ext OUTx OUTx 9 OUT2 10 OUT2 Output 2 Standard all locks and door bolts open 11 OUT3 12 OUT3 Output 3 Standard resistance monitoring input sabotaged 22 OUT4 23 OUT4 Output 4 Standard external...

Page 17: ...itoring of external power supply Output voltage 24 VAC power load at output 0 4 A at 25 C 0 3 A at 50 C ext NC 39 COM 40 NO 41 14 VDC 15 GND External power supply 12 VDC 24 VDC 700 200 mA ext I O box...

Page 18: ...as far as possible the keypad shows signs of wear over time revealing the individual numbers used in the code Example of a good password Memorable sentence First letters of each word First letters in...

Reviews: