500.0027-A
5
Subject to technical changes
8.
The green LED goes out to show that the new user code has been programmed.
9.
With the
door open
, press any numeric key and turn the rotary opening handle
counterclockwise into the "closed" position (lock closes automatically).
10.
Enter the new user code and within 3 seconds
after
you hear the triple acoustic signal
and see the green LED light up, turn the rotary opening handle clockwise.
11.
If the test opening of the lock was successful, the new user code has been
programmed and the safe interior can be closed (section 3.2.).
NOTE:
If errors occur when making the change or if there is a break of more than 10
seconds, the old code remains valid. You must start the programming procedure from the
beginning again.
Replacing the battery
If it is necessary to replace the battery (section 4.1.), keep to the following procedure:
1.
Purchase a battery (9V ALKALINE
block battery)
Note the expiration date!
2.
Using the lug positioned on the left
of the battery cover, carefully push
the battery cover to the right, out of
the input unit housing.
3.
Carefully pull the old 9V ALKALINE
block battery out of the input unit
housing towards the right, and
detach it from the cable.
4.
Connect the new 9V ALKALINE
block battery to the cable and push
the battery into the housing from
the right.
Push the cable above the battery
into the housing.
5.
Carefully push the battery cover
into the input unit housing again,
towards the left.
Avoid jamming the cable!
Lug