Connection
ENG
4. Connection
CAUTION
Electric shock caused by ingress of
moisture.
Personal injury and material damage.
X
Connect power supply using a
junction box.
X
Use a junction box suitable for wet
and damp locations.
NOTICE
Material damage caused by wrong
mains voltage.
Damage or destruction of the luminaire.
X
Connection by a skilled electrician
only.
X
Compare the mains voltage with
the nominal voltage and the fre-
quency specified on the rating
plate and make sure that they are
identical.
Colour of the
wire
Assignment
white
N
black
L
green
PE
pink
DALI / +
orange
DALI / -
Tab. 2: Terminal assignment with "DALI" or
"1-10 V" activation.
Colour of the
wire
Assignment
white
N
black
L
green
PE
Tab. 3: Terminal assignment with "ON/OFF" acti-
vation.
NOTE:
Observe the terminal assignment,
X
Connect the wires to a suitable power
supply.