22
Gas Conversion and Specifications
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Gas Regulator
NOTE: Gas
regulator
supplied
is
convertible between Natural Gas
and LP Gas, but it’s outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn ‘On’ gas supply and appliance.
3. Adjust pressure adjusting screw to achieve correct burner
operating pressure.
NOTE: Measure burner operating pressure at gas valve outlet
test point with burner operating at 'High Flame'
setting.
4.
Verify operating pressure remains correct (Re-adjust regulator if required).
5.
Screw cap nut back onto regulator.
Gas Type Labels
On completion of gas conversion, replace gas type labels located at:-
- Rear of unit, above gas connection.
- Beside rating plate.
Commissioning
Before leaving installation;
1. Check all gas connections for leakage using soapy water or other gas detecting equipment.
2. Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3. Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut ‘Off’ the
gas supply and contact the supplier of this appliance.
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning
Pressure Adjusting
Screw
Cap Nut
Summary of Contents for GP8450G