10 

Assembly 

 

All Models 

All models come pre-assembled. 

 

NOTE:  This appliance is fitted with adjustable feet to enable the unit to be positioned securely and 

level.  This should be carried out on completion of the electrical connection.  Refer to 
'Electrical Connection' section. 

 

Optional Accessories (Refer to Replacement Parts List) 

• 

Plinth Kit.  For installation details, refer to the instructions supplied with each kit. 

 

Electrical Connection 

NOTE: ALL ELECTRICAL CONNECTIONS MUST ONLY BE CARRIED OUT BY A QUALIFIED  

PERSON. 

 

Each appliance should be connected to an adequately protected power supply and isolation switch mounted 
adjacent to, but not behind the appliance.  This switch must be clearly marked and readily accessible in 

case of fire. 

 

1. 

Check that the electricity supply is correct as shown on the Rating Plate.  (Refer to the dimension 

drawings for rating plate location). 

2. 

The supply terminal connections are located at the rear of the the appliance.  Refer to ‘Electrical 

Connections’ in the ‘Specifications’ section of the manual. 

3. 

Remove the control panel to allow connection access for the electrical supply. 

4. 

Bring the supply cable up through the grommet at the back of the appliance and through the  

compression type gland provided on the rear of the main electrical switchgear panel. 

5. 

Connect the mains supply to L1, L2 and L3 fuse carrier connections for 3 phase and L1 for single 
phase (GP8600E). 

6. 

Connect neutral and earth conductors to neutral stud and earth stud respectively. 

7. 

For all connections ensure that conductors are secure and appropriately terminated. 

8. 

Tighten the cable gland to secure against tension on the cable. 

 

NOTE: 

• 

This appliance must be grounded / earthed. 

• 

Fixed wiring installations must incorporate an all-pole disconnection switch. 

 

9. 

Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs 

so that the appliance is level and at the correct height. 

10.  Connect the power supply to the appliance. 
11.  Check that the electrical supply is as shown in 'Specifications' section of this manual. 

Installation

 

C

AUTION

 

• 

This appliance is for professional use and is to be used by suitably  
qualified / trained persons only. 

• 

Only qualified service persons are to carry out installation and servicing of 
this appliance.

 

WARNING: 

 

T

HIS

 

APPLIANCE

 

MUST

 

BE

 

EARTHED

.  I

F

 

THE

 

SUPPLY

 

CORD

 

IS

 

DAMAGED

IT

 

MUST

 

BE

 

REPLACED

 

BY

 

A

 

SUITABLY

 

QUALIFIED

 

PERSON

 

IN

 

ORDER

 

TO

 

AVOID

 

A

 

HAZARD

Summary of Contents for GP8600E

Page 1: ...e r a t i o n M a n u a l Electric Griddle GP8600E GP8900E GP8120E Date Purchased Serial Number Dealer Service Provider 229350 12 For use in GB IE I n s t a l l a t i o n a n d O p e r a t i o n M a n...

Page 2: ...1 0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NE...

Page 3: ...al Electrical Supply Requirements Electrical Connection Dimensions Installation 9 Installation Requirements Unpacking Location Clearances Assembly Electrical Connection Commissioning Operation 12 Oper...

Page 4: ...ION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS A...

Page 5: ...ddle 1200 mm wide Bench Model GP 1 8120E CB Electric Griddle 1200 mm wide with Cabinet Base GP 1 8120E LS Electric Griddle 1200 mm wide on Leg Stand GP 1 8120E RB Electric Griddle 1200 mm wide with Re...

Page 6: ...s per AS NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g H05 RN F Type The branch supply line shall be individually overload protected to the correct current rating and the supply chord shall be protect...

Page 7: ...5 Dimensions GP L 8600E B GP L 8900E B GP L 8120E B Dimensions for Bench Models Rating Plate Location for this option R R...

Page 8: ...6 Dimensions GP L 8600E CB Dimensions for Cabinet Base Models Rating Plate Location for this option R GP L 8900E CB GP L 8120E CB R...

Page 9: ...7 Dimensions GP L 8600E LS GP L 8900E LS GP L 8120E LS Dimensions for Leg Stand Models Rating Plate Location for this option R R...

Page 10: ...8 Dimensions GP L 8900E RB GP L 8120E RB Dimensions for Refrigeration Base Models Rating Plate Location for this option R R...

Page 11: ...are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic coating from the exterior stainless steel pa...

Page 12: ...ing the supply cable up through the grommet at the back of the appliance and through the compression type gland provided on the rear of the main electrical switchgear panel 5 Connect the mains supply...

Page 13: ...tor has been instructed in the areas of correct operation and shutdown procedure for the appliance 2 This manual must be kept by the owner for future reference and as a record of Date of Purchase Date...

Page 14: ...supply the green neon will illuminate 2 Turn the thermostat control knob to the desired temperature When the amber neon goes out the desired temperature has been reached and the griddle is ready for u...

Page 15: ...down before cleaning NOTE DO NOT use abrasive detergents strong solvents or caustic detergents as they could corrode or damage the griddle In order to prevent the forming of rust on the griddle plate...

Page 16: ...e Steel Plate NOTE In order to prevent the forming of rust on the griddle plate ensure that all detergent and cleaning material has been entirely removed after each cleaning process The appliance shou...

Page 17: ...water a mild detergent solution and a soft scrubbing brush Note that the control knobs are a push fit onto the spindles and can be removed to allow cleaning of the front control panel b Baked on depo...

Page 18: ...on The Model Trade Name and the Serial Number of the Appliance both can be found on the Technical Data Plate located on the appliance Refer to the Dimensions section For the Refrigeration Cabinet Faul...

Page 19: ...EON GREEN 227962 NEON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31 7 11 22 32 12 3 P3 4 P4 CONTROL PANEL GRIDDLE PLATE 21 31 11 22 32 12 9 9 9 1 1 1 3 2 2 7 7 6 9 9 9 7 6 8 4 4 5 8 10 11 12 EARTH STU...

Page 20: ...EON GREEN 227962 NEON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31 7 11 22 32 12 3 P3 4 P4 CONTROL PANEL GRIDDLE PLATE 21 31 11 22 32 12 9 9 9 1 1 1 3 2 2 7 7 6 9 9 9 7 6 8 8 4 4 5 10 10 11 12 EARTH...

Page 21: ...DLE PLATE 21 31 11 22 32 12 15 16 15 16 REAR SUPPLY ENTRY THERMOSTAT 229146 SWITCH 229145 2 1 P2 P1 NEON AMBER 227963 NEON GREEN 227962 OVERTEMP THERMOSTAT 229353 21 31 11 22 32 12 3 P3 4 P4 21 31 11...

Page 22: ...EON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31 11 22 32 12 3 P3 4 P4 21 31 11 22 32 12 THERMOSTAT 229146 SWITCH 229145 2 1 P2 P1 NEON GREEN 227962 NEON AMBER 227963 OVERTEMP THERMOSTAT 229353 21 31...

Page 23: ...Models only 228801 Refrigeration Base 900 mm Plinth Kit RB Models only 228805 Refrigeration Base 1200 mm Plinth Kit RB Models only 227850 Leg 150 mm Adjustable Flush Stud CB and RB Models 227851 Leg 1...

Page 24: ......

Reviews: