3
Specifications
Model Numbers Covered in this Specification
GP
[1]
8910E
Electric Griddle Range, Static Oven
900 mm wide.
GP
[1]
8910EC
Electric Griddle Range, Convection Oven
900 mm wide.
NOTE:
[1]: - Model Options;
- -
Standard.
L
- Low Back.
B
- Bold Front.
LB
- Low Back and Bold Front.
General
A commercial heavy duty, 900mm wide, Electric Griddle Range, designed for modular kitchens and
constructed in an easy clean stainless steel external finish. The griddle elements are constructed
using stainless steel sheathed heating elements with dual thermostatic control zones.
The Griddle uses a 20mm thick griddle plate with the option of either ribbed or chromed mirror plate
options.
The range can be equipped with either an electric 6.5kW convection or static oven, 900mm wide.
Electrical Supply Requirements
Electrical Connection
Electrical supply connection point is located at the rear of the appliance, approximately 80 mm from
the right hand side and 467 mm from the rear and 150 mm from the floor.
When connecting a Waldorf electric appliance to the main supply, ensure that the following is carried
out:-
An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in
such a position that the user does not have to reach across the cooking surface.
Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary pol-
ychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS 3191
part 2.10.11. or IEC 60245-IEC-57) e.g. H05 RN-F Type.
The branch supply line shall be individually overload protected to the correct current rating
and the supply chord shall be protected against any mechanical or thermal damage.
A grommet is fitted around the wiring entry hole into the appliance.
All wiring connections must be tight.
Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance
for the current drawn on that line.
MODEL
Fan Motor
GP8910E
18.5 kW
L1 - 24.6 Amps
L2 - 25.6 Amps
L3 - 25.6 Amps
---------
GP8910EC
18.9 kW
L1 - 25.9 Amps
L2 - 25.6 Amps
L3 - 25.6 Amps
100W
3-Phase Connection
3P+N+E
400-415V, 50/60Hz
WARNING:
T
HIS
APPLIANCE
MUST
BE
EARTHED
. I
F
THE
SUPPLY
CORD
IS
DAMAGED
,
IT
MUST
BE
REPLACED
BY
A
SUITABLY
QUALIFIED
PERSON
IN
ORDER
TO
AVOID
A
HAZARD
.