background image

Specifications

 

Electrical Supply Requirements 

 

Electrical Connection 

GP8910GE / GEC 

Electrical supply connection point is located at the rear of the appliance, approximately 80 mm from 
the right hand side and 466 mm from the rear and 150 mm from the floor. 

 

GP8121GE / GEC 

Electrical supply connection point is located at the rear of the appliance, approximately 380 mm from 

the right hand side and 466 mm from the rear and 150 mm from the floor. 

 

When connecting a this electric appliance to the mains supply, ensure that the following is carried 

out:- 

• 

An isolating switch is fitted within 2 m of the appliance, but not on the appliance and in 
such a position that the user does not have to reach across the cooking surface. 

• 

Supply cord shall be oil-resistant, sheathed flexible cable and not lighter than ordinary 
polychloroprene or other equivalent synthetic elastomer sheathed cord (as per AS / NZS  

3191 part 2.10.11. or IEC 60245-IEC-57) e.g. HO5 RN-F Type. 

• 

The branch supply line shall be individually overload protected to the correct current rating 
and the supply chord shall be protected against any mechanical or thermal damage. 

• 

A grommet is fitted around the wiring entry hole into the appliance. 

• 

All wiring connections must be tight. 

 

Refer to the appropriate wiring standards for the size of cable that is to be supplied to an appliance 

for the current drawn on that line. 

WARNING: 

 

T

HIS

 

APPLIANCE

 

MUST

 

BE

 

EARTHED

.  I

F

 

THE

 

SUPPLY

 

CORD

 

IS

 

DAMAGED

IT

 

MUST

 

BE

 

REPLACED

 

BY

 

A

 

SUITABLY

 

QUALIFIED

 

PERSON

 

IN

 

ORDER

 

TO

 

AVOID

 

A

 

HAZARD

MODEL 

1-Phase Connection 

1P+N+E 

230-240V 

3-Phase Connection 

3P+N+E 

400-415V 

GP8910GE 
GP8121GE 

6.5 kW,  

26.6 Amps @ 235V 

6.5 kW 

L1 - 8.2 Amps 

L2 - 9.2 Amps 

L3 - 9.2 Amps 

GP8910GEC 
GP8121GEC 

6.8 kW, 

27.9 Amps @ 235V 

6.8 kW 

L1 - 9.5 Amps 

L2 - 9.2 Amps 

L3 - 9.2 Amps 

Summary of Contents for GP8910GE

Page 1: ...n d O p e r a t i o n M a n u a l GP8910GE GP8910GEC GP8121GE GP8121GEC Gas Griddle Range Electric Oven Date Purchased Serial Number Dealer Service Provider 230560 12 For use in GB IE GPL8910GE GPL891...

Page 2: ...0257 Fax 336 661 9546 CANADA Serve Canada 22 Ashwarren Road Downview Ontario M3J1Z5 Toll Free 800 263 1455 Ph 416 631 0601 Fax 416 631 0315 info servecanada com www servecanada com www moffat com NEW...

Page 3: ...ctrical Supply Requirements Electrical Connection Dimensions 6 Installation 7 Installation Requirements Unpacking Location Clearances Assembly Rear Roller Fitting Gas Connection Electrical Connection...

Page 4: ...INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE WARNING INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS G...

Page 5: ...ls and optional Non UK models are fitted with an overtemp device which isolates the gas supply to the burners should the gas control system or thermostat malfunction thus preventing overheating of the...

Page 6: ...pliance 32 mm from the rear and 655 mm from the floor and is entered from beneath the appliance An optional underside connection is available Connection is BSP male Natural Gas LP Gas Propane GP8910GE...

Page 7: ...not lighter than ordinary polychloroprene or other equivalent synthetic elastomer sheathed cord as per AS NZS 3191 part 2 10 11 or IEC 60245 IEC 57 e g HO5 RN F Type The branch supply line shall be in...

Page 8: ...6 Dimensions GP L 8910GE GEC GP L 8121GE GEC...

Page 9: ...an authorised service agent They are not to be adjusted by the installation person Unpacking Remove all packaging and transit protection from the appliance including all protective plastic coating fr...

Page 10: ...aise the appliance from the floor by approx 75mm using suitable lifting equipment i e Palletiser Forklift to allow the rear adjustable feet to be removed 2 Unscrew and remove both the rear adjustable...

Page 11: ...ween Natural Gas and LPG as per the Gas Conversion Section in this manual Ensure the regulator is converted to the correct gas type that the appliance will operate on The regulator outlet pressure is...

Page 12: ...e Specifications Section 5 Connect neutral and earth conductors to neutral stud and earth stud respectively 6 For all connections ensure that conductors are secure and appropriately terminated 7 Tight...

Page 13: ...y Ensure that the operator has been instructed in the areas of correct lighting operation and shutdown procedure for the appliance This manual must be kept by the owner for future reference and a reco...

Page 14: ...GP8121GE Convection Oven GP8910GEC GP8121GEC Piezo Igniters Ignites the Griddle Pilot Burners Gas Griddle Controls OFF Position PILOT Burner Temperature Gradient Fig 5 Oven Thermostat Control OFF Posi...

Page 15: ...r button on the front control panel 2 Rotate the gas control knob anti clockwise to the desired temperature marked on the knob 3 The main burner will now ignite automatically off the pilot burner Re S...

Page 16: ...t to a high setting proportionally more heat is produced at the top of the oven This can be used for browning etc during the cooking operation With the oven top heat control set on a low setting less...

Page 17: ...le plate Steel Plate ensure that any detergent or cleaning material has been completely removed after each cleaning The appliance should be switched on briefly to ensure the griddle plate becomes dry...

Page 18: ...s are worn during the cleaning process DO NOT use harsh abrasive detergents strong solvents or caustic detergents as they will damage the range and burners DO NOT use water on the griddle plates while...

Page 19: ...may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner when the appliance is cold and rub in the direction of the grain c Remove the grease drawer and clean w...

Page 20: ...s are not empty Call the service provider Pilot goes out when gas control knob released Releasing knob before the thermocouple has heated Pilot flame too small Gas pressure too low Partially blocked p...

Page 21: ...19 GP8910GE and GP8121GE Wiring Schematics...

Page 22: ...20 Wiring Schematics Wiring Diagram GP8910GE GP8121GE...

Page 23: ...21 GP8910GEC and GP8121GEC Wiring Schematics...

Page 24: ...22 Wiring Schematics Wiring Diagram GP8910GEC GP8121GEC...

Page 25: ...f the front sill 7 Replace with the correct size injectors Refer to Gas Specifications Table for injector sizes 8 Ensure that the aeration sleeve is pushed fully IN into the burner and locked in posit...

Page 26: ...e gas control knob from the front control panel The knob is a push fit onto the shaft of the gas control valve 2 Remove the gas griddle control panel from the front of the gas griddle by removing the...

Page 27: ...in and re fit it back to the cap the correct way for the gas type to be used Either LP or NAT should be visible on the flank of the pin once re fitted to the cap 4 Screw the cap back into the regulato...

Page 28: ...rner Check the Low Fire Burner operation Check the High Fire Burner operation Check the Oven Controls operation Ensure that all the Controls operate correctly Ensure that the Operating Pressure remain...

Page 29: ...section for details Natural Gas G20 Propane G31 GP8910GE GEC GP8121GE GEC GP8910GE GEC GP8121GE GEC Main Burner Injector 3 00mm 2 85mm 1 80mm 1 70mm Pilot Burner Injector 0 41 Low Fire Adjustment 1 Fu...

Page 30: ...0 41mm 019594 Pilot Injector LPG 0 25mm 228531 Regulator RV48CLM Natural Gas LPG convertible BSP F F Oven 228082 Oven Top Element 2kW 228059 Oven Bottom Element 4 5kW 227963 Neon Orange 227962 Neon G...

Page 31: ...craper Blade Individual Blade 228800 900mm Plinth Kit 900mm Range 228804 1200mm Plinth Kit 1200mm Range Gas Conversion Kits Replacement Parts List Griddle Plate Standard Chromed C Ribbed Chromed Optio...

Page 32: ...30...