The picture shows five page groups, divided into the sections
Sound, Multi, Instrument
and
Global.
Each group has a select key
햷
…
햻
and an activation LED below.
• The
Sound
parameters refer to a Sound program. If you are in Sound mode, you
will edit the currently played program. If you are in Multi mode, the Sound
program for the currently selected Instrument will be edited.
• The
Multi
parameters refer to a Multi program. They determine the common setting
for all instruments in the Multi program. Obviously, you can access these
parameters only when the MicroWave II/XT/XTk is in Multi mode.
• The
Instrument
parameters also refer to a Multi program. They determine the
individual setting of each instrument in the Multi program. Again, you have to be
in Multi mode to access these parameters.
• The
Global
parameters provide the basic settings of the MicroWave II/XT/XTk,
valid for all programs.
☞
This is how you access a specific parameter:
1. Locate the page group on the front panel and press the corresponding select key
햷
…
햻
below.
2. The display changes to a set of 4 parameters from the first page of the selected
group. For example, if you press the leftmost select button
햻
the parameters for
Oscillator 1 will be shown:
For a few seconds the page name is shown in the upper right corner of the display.
In our given example
[Osc1 1]
will be displayed for "Oscillator 1 Page 1". Some
units of the MicroWave II/XT/XTk, e.g. the oscillators, have several parameter pages
which are indexed by a page number.
When single mode is selected, you can only play and edit sound programs. If you try to
access a Multi mode parameter, you will get an error message in the upper right corner:
If you did some editing before the MicroWave II/XT/XTk was last powered on, the
display may show a different page than the first after pressing the select key. This is an
important feature: The MicroWave II/XT/XTk memorizes the last selected page to
speed up editing. When you re-enter the page group, you will find yourself where
you had left it last time.
3. Use the page dial
햴
to scroll through the page group:
Play Sound A001[Multi Mode not active]
Saw repeat
WMF |
Sound
|
100
Octave 1|Semitone | Detune
|Ke[Osc1 1]
-1
|
+07
|
+00
|
+100%
26
User’s Manual MicroWave II • MicroWave XT • XTk