PrgChange
sound / multi / combined
Determines the way MIDI Program Change messages are processed.
• If
sound is selected, program changes are used to select Sound programs for the
Instrument that receives on the corresponding MIDI channel.
• If
multi is selected, the whole Multi program is switched by program changes, that
are received on the basic channel set above.
• If
combined is selected, Instrument programs can be changed by using the
Instrument’s channel, the Multi can be changed by using the basic channel.
BendRange
0…120 / harmonic
Determines the intensity of the pitchbend via MIDI Pitchbend messages in semitones. If
harmonic is selected, the pitchbend is performed in steps of the harmonic and subharmonic
scale. Please refer to the chapter "Oscillator" to get further information about the harmonic
scale. This setting is valid for all programs whose oscillator
Pitchbend Range
parameter is
set to
global.
Device ID
0…126
Defines the device identification number for system exclusive data transmission.
Transmission will only be executed successfully if the sender and receiver setting coincide.
Device ID
127 is a so-called broadcast ID that addresses all connected MicroWave
II/XT/XTks. The MicroWave II/XT/XTk can receive this from other devices, but cannot send it
itself. This function is limited to special computer software.
Par. Control Send
off / Ctl only / SysEx / Ctl+SysEx
Determines which type of data is sent from the MicroWave II/XT/XTk via MIDI.
• If
off is selected, no data is sent.
• If
Ctl only is selected, only controller messages are sent. Parameters without
dedicated controller assignment are not sent at all.
• If
SysEx is selected, only system exclusive data is sent. This has the advantage that
the parameter change is not channel based but instrument based, which can avoid
unwanted parameter changes of layered sounds. The disadvantage is a larger
amount of data that is transferred.
• If
Ctl+SysEx is selected, both controller messages and system exclusive data is sent.
Par. Control Receive
off / on
Enables or disables the receiving of parameter control messages via MIDI. These messages
include controller and system exclusive data.
MIDI Clock Send
off / on
Enables or disables the sending of MIDI clock. This setting should be enabled in those
cases, where you want to use the MicroWave II/XT/XTk’s arpeggiator as master for
controlling the tempo.
When MIDI Clock Send is enabled while the MicroWave II/XT/XTk’s MIDI In and Out
are connected to your sequencer, you will probably get a MIDI loop. A total hangup
of your system may result. Ensure to disable the MicroWave II/XT/XTk’s MIDI clock
sending feature in such a case.
94
User’s Manual MicroWave II • MicroWave XT • XTk