Gas Conversion and Specifications
Gas Specifications
- Australia / New Zealand Only:
- UK Only:
Appliance Classification
Category:
II
2H3P
(20, 30 / 37).
Flue Type:
A
1.
* - Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through the appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Natural. Gas (G20)
Propane (G31)
Open Burners
Main Burner Injectors
Ø 2.45 mm
Ø 1.50 mm
Pilot Burner ('PF' Option Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Main Burner
Ø 2.40 mm
Ø 1.40 mm
Pilot Burner
0.35
0.23
Low Fire
0.90 mm
0.55 mm
Burner Aeration Setting
Fully Open
10 mm
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Operating Pressure
0.95 kPa (*)
2.6 kPa (*)
Gas Regulator Cap Screw
Oven
Natural Gas (G20)
Propane (G31)
Open Burner
Main Burner Injectors
Ø 2.30 mm
Ø 1.40 mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Griddle
Main Burner
Ø 2.10 mm
Ø 1.30 mm
Pilot Burner
0.35
0.23
Main Burner
Ø 2.40 mm
Ø 1.40 mm
Pilot Burner
0.35
0.23
Low Fire
Ø 0.90 mm
Ø 0.55 mm
Supply Pressure
20 mbar
30 / 37 mbar
Operating Pressure
9.5 mbar (*)
26 mbar (*)
Gas Regulator Cap Screw
Oven
Burner Aeration Setting
Fully open
10 mm