26
Gas Conversion and Specifications
Gas Specifications
- Australia
- New Zealand
- United Kingdom
Category:
II
2H3P
(20, 37).
Flue Type:
A
1.
NOTE: Measure burner operating pressure at manifold test point with two burners operating at full setting.
Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted, apart from
when carrying out Gas Conversion, if required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas (G20)
Propane (G31)
Open Burner
Main Burner Injectors
Ø 2.30mm Ø
1.40mm
Pilot Burner ('PF' Models only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø
1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
20 mbar 37
mbar
Burner Operating Pressure (*)
9.5 mbar 26
mbar
Gas Regulator Cap Screw
Natural. Gas
LP Gas (Propane)
Open Burner
Main Burner
Ø 2.45mm Ø
1.50mm
Pilot Burner ('PF' Models Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø
1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
1.13 - 3-40 kPa 2.75 - 3-40 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Regulator Cap Screw
Natural. Gas
LP Gas
Open Burner
Main Burner
Ø 2.45mm Ø
1.50mm
Pilot Burner ('PF' Models Only)
0.30 0.20
Griddle
Main Burner
Ø 2.10mm Ø
1.30mm
Pilot Burner
0.35 0.23
Burner Aeration Setting
Fully open
Fully open
Supply Pressure
1.13 - 3-40 kPa 2.75 - 3-40 kPa
Burner Operating Pressure (*)
0.95 kPa 2.6 kPa
Gas Regulator Cap Screw