Operation Guide 

1. 

Waldorf Salamanders have been designed to provide simplicity of operation and 100% safety  

protection. 

2. 

Improper operation is almost impossible, however bad operation practices can reduce the life of the 
salamander and produce a poor quality product.  To use this salamander correctly please read the 

following sections carefully:- 

 



Lighting the Main Burners. 



Racking System. 



Cooking Recommendations. 

 

Description of Controls 

The salamander has individual heat controls for left and right sides.  Select desired heat level and allow a 

few minutes for elements to heat up. 

 



Waldorf salamanders provide two independently controlled heat zones. 



High speed grilling is provided by two infrared gas burners in ceiling of grilling compartment. 



Left hand and right hand gas control knobs operate the left side and right side burners respectively, 
independently of each other. 



Each burner is provided with piezo ignition and flame failure protection for main burner. 

Gas Control Knobs 

 

 

    OFF Position. 

  HIGH Flame. 

  LOW Flame. 

Rack Handles

 

Fig 6 

Piezo Igniter 

 

 
 



This appliance is for professional use and is only to be used by qualified 
persons. 



Only authorised service persons are to carry out installation, servicing or gas 
conversion operations. 



Components having adjustments protected (e.g. paint sealed) by the 

 

manufacturer should not be adjusted by the user / operator. 

Caution 

Summary of Contents for SN8200G

Page 1: ...I n s t a l l a t i o n a n d O p e r a t i o n M a n u a l Gas Salamander SN8200G SN8200GB Date Purchased Serial Number Dealer Service Provider 231921 10 For use in GB IE ...

Page 2: ...es tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel...

Page 3: ...ht Installation 6 Installation Requirements Unpacking Location Clearances Wall Mounting to non combustible wall only Gas Connection Commissioning Operation 11 Operation Guide Description of Controls Lighting Main Burners Racking System Cooking Recommendations Cleaning and Maintenance 13 General Racking Stainless Steel Surfaces Vitreous Enamel Surfaces Trough Tray Fault Finding 15 Gas Conversion an...

Page 4: ... BE LEFT ON UNATTENDED IT IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION Warning This appliance is for p...

Page 5: ...changed from flat to angled position by partial removal of rack Rack height must be fully removed for repositioning of rack height setting Branding Plate is available as an accessory item Refer to Replacement Parts List SN8200GB Rack supports have 4 fixed height positions offering flat and angled rack positioning Rack can be changed from flat to angled position by partial removal of rack Rack heig...

Page 6: ...t the back 128mm from right hand side of appliance and entered from beneath appliance Connection is BSP male Natural G20 Propane G31 Heat Input Gross Nominal 8 8 kW 8 8 kW Reduced 3 6 kW 2 6 kW Gas Rate Nominal 0 84 m3 hr 0 63 kg hr Reduced 0 34 m3 hr 0 19 kg hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure 10 mbar 26 mbar Gas Connection 1 2 BSP Male Natural Gas LP Gas Input Rating 31 ...

Page 7: ... Dimensions Width 685mm Height 230mm at front Depth 330mm Cooking Area Rack 610mm x 310mm Branding Plate Accessory 610mm x 310mm Weight Nett 41kg without Branding Plate or Racking System Plan 900 128 32 401 424 25 GAS ENTRY Front Side ...

Page 8: ...e adjusted by the installation person Unpacking Remove all packaging and transit protection from appliance including all protective plastic coating from exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to carrier and distributor Report any deficiencies to distributor who supplied appliance Check available gas supply is correct to that shown on rati...

Page 9: ...on combustible material NOTE Do not obstruct or block appliances flue Never directly connect a ventilation system to appliance flue outlet Clearances NOTE Only non combustible materials can be used in close proximity to this appliance We recommend a clearance of 100mm on either side of appliance to allow access to side panels for servicing purposes Using wall mounting accessories provided with thi...

Page 10: ...lastic spacers to top rear corners of unit Leave them unscrewed by approximately 5mm 3 Fit two adjusting screws bolts into nutserts at bottom rear corners of unit These should protrude approximately 30mm from rear of Salamander 4 Lift Salamander onto wall bracket lining up black plastic spacers on salamander with mounting notches in bracket 5 Lower Salamander onto mounting bracket 6 Tighten black ...

Page 11: ... regulator supplied into gas supply line as close to appliance as possible Refer to Specifications section for gas supply location dimensions NOTE Gas pressure regulator provided with this appliance is convertible between Natural Gas and LPG as per Gas Conversion Section in this manual Ensure regulator is converted to correct gas type that appliance will operate on Regulator outlet pressure is fix...

Page 12: ...on b Ensure the operator has been instructed in areas of correct lighting operation and shutdown procedure for appliance 2 This manual must be kept by owner for future reference and a record of Date of Purchase Date of Installation and Serial Number of Unit recorded and kept with this manual These details can be found on Rating Plate attached to R H side panel refer to Gas Connection section NOTE ...

Page 13: ...t up Waldorf salamanders provide two independently controlled heat zones High speed grilling is provided by two infrared gas burners in ceiling of grilling compartment Left hand and right hand gas control knobs operate the left side and right side burners respectively independently of each other Each burner is provided with piezo ignition and flame failure protection for main burner Gas Control Kn...

Page 14: ...ck area so toasting cheese melting and grilling should be relatively even wherever food is placed 2 The HIGH position is recommended for most grilling cheese melting functions and LOW for a reduced heat 3 For cooking food through rather than just surface browning rack position three and four from the top is recommended 4 With Branding Plate fitted unit is able to aid the chef in its ability to pro...

Page 15: ...move left and right hand side racks from unit by removing single securing screw from each of side racks 5 Withdraw left and right hand side racks from unit 6 Refit racking in reverse order once cleaning has been completed Stainless Steel Surfaces Clean with detergent Baked on deposits or discolouration may require a good quality stainless steel cleaner or stainless steel wool Always apply cleaner ...

Page 16: ...gas control knobs from gas tap spindles by pulling knobs away from control panel b Remove drip tray from appliance c Remove two screws on underside of control panel securing control panel to hob d Remove control panel from front of appliance e Remove 2 screws holding shaft plate to gas control body and remove control shaft and plate See Fig 9 Note orientation of shaft for correct re assembly f Usi...

Page 17: ...rol knob released Releasing knob before thermocouple has heated Main Burner flame too small Gas pressure too low Partially blocked main injector Thermocouple faulty Hold knob in for at least 20 seconds following ignition of main burner Call service provider Call service provider Main burners will not light No gas supply Incorrect supply pressure Blocked main injector Faulty gas control Ensure gas ...

Page 18: ...s panels Main burner injectors 2 Remove main burner injectors and replace with correct size injectors as shown in Gas Specifications tables at rear of this section Low Fire Adjustment 1 Remove the following Gas control knobs from front of unit Two front control panels 2 Light main burners and check flame size on Low position Adjust burner gas control valve low fire adjustment screw as shown in Gas...

Page 19: ...installation 1 Check all gas connections for leakage using soapy water or other gas detecting equipment 2 Carry out a Commissioning check of appliance as shown in Installation Section of this manual 3 Ensure any adjustments done to components that have adjustments settings paint sealed are to be re sealed NOTE If for some reason it is not possible to get appliance to operate correctly shut Off gas...

Page 20: ...d Refer to Gas Conversion section for details Natural Gas G20 Propane G31 Main Burner Injectors Ø 1 85mm Ø 1 15mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w turn out c c w Operating Pressure 10 mbar 26 mbar Gas Regulator Cap Screw Supply Pressure 20 mbar 37 mbar Natural Gas LP Gas Main Burner Injectors Ø 1 85mm Ø 1 15mm Low Fire Size Ø 1 00mm Ø 1 00mm Adjustment 2 turns out c c w...

Page 21: ...e 227508 Piezo Ignitor General 026096 Wall Mounting Bracket 017963 Rack 013395 Rack Handle 026093 Side Rack 227961 Screw Side Rack 227950 Trough Tray Accessories Optional 013418 Branding Plate Australia Only Gas Regulator Gas Conversion Kits Model Gas Type to Convert to Australia New Zealand Only Nat Gas LPG Nat Gas LPG SN8200G GB 232057 232056 232057 232056 UK Only Gas Type Gas Regulator Part No ...

Page 22: ......

Reviews: