Camlock Coupling
•
The camlock couplings are used to connect
the piping to pickup hoses.
•
They are designed for quick and easy connect
and release.
•
A rubber seal is
installed in the
opening of the
coupling to ensure
proper connection and to prevent connection leaks.
•
When installing a camlock coupling, be sure to
have a ring of silicone around the piping and have the coupler closed.
•
Camlocks must be installed with dust plugs inserted to ensure gasket is not
pushed out by pipe
•
After installing the coupler, attach the chain from the dust plug to the
Camlock coupling.
•
This ensures that the dust cap will not be lost when an operator is using the
Central Vac system.