background image

This document consists of instructions of Smart Indicating System, which includes technical

parameters, function instructions and notices of following components:

RFID reader

WH-SR1000

RFID tag

Tag-RRL100

RFID tag

Tag-DRL100

Please note:

1. For above components, the exterior looking, parameters and other technical details of products

may vary from which are provided in this document. It can be due to technical updates without

official notices.

2. Above components, as industrial grade products, shall be implemented and modified by

specialists, who are reasonably considered as qualified, in order to ensure its technical integrity.

FCC CAUTION:

Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy, and if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is

connected.

Consult the dealer or an experienced radio/TV technician for help.

FCC 20cm Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with a minimum distance of 20c
mbetween the radiator & your body. This transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.

Summary of Contents for Tag-DRL100

Page 1: ...1 Smart Indicating System Product Instruction User Manual...

Page 2: ...r Walk Horizon product names referenced herein are trademarks of Walk Horizon Technology Beijing Co Ltd and may be registered in certain jurisdiction Other product names designations logos and symbols...

Page 3: ...for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment g...

Page 4: ...rget Usage Scenario 2 Exterior 3 Parameters 4 Common Failures Addressing 4 RFID Tag Tag RRL100 Tag DRL100 5 Features 5 Target Usage Scenario 6 Exterior 6 Parameters 7 Common Failures Addressing 8 Syst...

Page 5: ...RFID tags Receiving encrypted wireless signals from RFID tags Transmission to the backbone via Ethernet Receiving signals from the backbone via cable and Ethernet Signal transferring encrypting and de...

Page 6: ...y guaranteeing the reliability at certain level 4 Supports full duplex communication with active tags Tag RRL100 and Tag DRL100 pass operational signals to and collecting feedback heartbeat signals fr...

Page 7: ...each time when the reader receives a Feedback signal from a tag 6 Indicating light RF3 RF channel 3 working status indicator light status reverses each time when the reader receives a Heartbeat signal...

Page 8: ...5 95 no condensate water Electrical Common Physical Operating Voltage DC 5V Operating Current 1A Exterior Material Aluminum Alloy Size 200mm length 145mm width 60mm height Weight 0 75 kg Common Failur...

Page 9: ...can be seen as the trigger of certain IT functions Transmitting Heartbeat signal to a reader at a certain time interval as the indicator of its operating status Features 1 Simultaneously operating wit...

Page 10: ...t Usage Scenario Light indicating under data center facility management scenario Vehicle indicating under car parking or manufacturing scenario Stored inventory indicating under warehousing scenario E...

Page 11: ...Low Voltage Alert Default local alert via an indicating light Battery Life 9 hours over 1 5 years self discharge considered or 240 hours constant on heartbeat every 60 seconds Battery Tag RRL100 ER18...

Page 12: ...mine itself as the target tag and then switch on the LED on itself 3 If the button of a tag both types is clicked the tag will send a encrypted Feedback signal to the reader via its transmission modul...

Page 13: ...9 Walk Horizon Technology Beijing Co Ltd 2017 Address Room 121 Building B1 Shouxindasha 5 Jiangtai Road Chaoyang District Beijing 100015 China Phone 8610 8208 8750 Web www walkhorizon com...