6
INSTALLATION
BATTERY INSTALLATION:
The battery used in the BUX BM
2
-13PB series should be a BCI group 22NF style battery of
the deep discharge type. It should have a minimum reserve capacity of 45 ampere-hour @ 20
hour rate (e.g. Dynasty DCS-50U). The battery used in the BUX BM
2
-25PB, BUX BM
2
-36PB,
BUX BM
2
-50PB, BUX BP
2
-7PB or BUX BP
2
-15PB series should be a BCI group 27 style battery
of the deep discharge type. It should have a minimum reserve capacity of 82 ampere-hour @
20 hour rate such (e.g. Dynasty DCS-88BT). Replacement batteries must be 12 volt, top lug
terminal, low maintenance, AGM type, and should have the highest reserve capacity available
and be rated for deep cycle discharge. O.S. Walker does not recommend the use of wet lead
acid batteries. After installing the battery Program Your Magnet reference page 18.
ADANGER
BATTERY GAS CAN EXPLODE. KEEP SPARKS
AND FLAMES AWAY FROM BATTERIES.
IMPORTANT:
CHARGER MAY BE PERMANENTLY DAMAGED IF BATTERY CABLES
ARE REVERSED. BE SURE CABLES ARE CONNECTED WITH CORRECT POLAITY.
Install battery with the positive terminal towards the rear of the magnet.
■
FIRST,
connect the red battery cable to the positive post, ) and cover with the
terminal boot.
■
THEN,
connect the black battery cable to the negative post, marked(-).
BATTERY CHARGING
Read and understand the instructions supplied with your battery. After installation, the battery
should be charged as soon as possible to avoid loss of life. Make sure the battery has been
fully charged before placing the magnet into service.
NEVER ATTEMPT TO CHARGE A DAMAGED OR FROZEN BATTERY. Charge the battery
in a well ventilated area. Battery gases are explosive. KEEP SPARKS AND FLAMES
AWAY FROM THE BATTERY.
Turn the built in charger on by connecting the control unit to the 115 VAC line using the line
cord shipped with your battery powered lift magnet. For the charger to operate, the magnet
must be turned off.
The battery charger is designed to monitor the battery voltage and current during the charging
cycle to prevent damage to the battery. The charger has the capacity to restore the charge to
a healthy battery during non-production shifts. Recharging the battery every night is recom
mended to increase battery life and maximize your magnet's operating time.
ADANGER
NEVER DISCONNECT THE MAGNET FROM ITS POWER SOURCE WHILE IT IS
ENERGIZED! ELECTRICAL ARCING WILL OCCUR AND MAY CAUSE SERIOUS
INJURY.
O.S. Walker Inc., Battery Powered Magnets