800-WMAGNET
12 of 33
The external adjustment for the number of demagnetization pulses per Release cycle is done using the full, residual, release
pushbuttons, and the Variable potentiometer. To adjust the number of release pulses, the control must be “at the end of the
release cycle”. The procedure for externally adjusting the number of Release pulses is as follows:
1. Hold the Release button down and PRESS the Full button. With some control revisions you may have to press the Full
button again after you have let go of the Release button.
2. Using the table below, you can adjust the number of release pulses by turning the Variable adjustment knob.
Number of Release Pulses
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
Variable Lamp/LED
X
X
X
X
X
X
X
X
Residual Lamp/LED
X
X
X
X
X
X
X
X
Full Lamp/LED
X
X
X
X
X
X
X
X
Release Lamp/LED
X
X
X
X
X
X
X
X
X indicates lamp/led is on.
3. Once the number of desired Release pulses has been set, PRESS the Residual button.
4. The control is now ready for operation.
The internal adjustment for the number of demagnetization pulses per Release cycle is located on the main pc board.
The procedure for internally adjusting the number of release pulses is as follows:
1. Turn off power to the control and open the enclosure.
2. Remove JP1 Jumper (Pot Disable) located on the main pc board.
NOTE: THE EXTERNAL ADJUSTMENT WILL NOT OPERATE WITHOUT JP1 INSTALLED.
3. Turn P1, with a small straight bladed insulated screwdriver, clockwise to increase the number of pulses or counter-
clockwise to decrease the number of pulses.
4. Close the enclosure and restore power.
Summary of Contents for IMI Smart-D Series
Page 18: ...800 WMAGNET 18 of 33 5 6 Smart 75 100D Panel Layout Figure 5 1 Smart 75 100D Panel...
Page 19: ...800 WMAGNET 19 of 33 5 7 Smart 20 30 50D Panel Layout Figure 5 2 Smart 20 30 50D Panel...
Page 20: ...800 WMAGNET 20 of 33 5 8 Smart 7 10 15D Panel Layout Figure 5 3 Smart 7 10 15D Panel...
Page 21: ...800 WMAGNET 21 of 33 5 9 Smart 3 5D Panel Layout Figure 5 4 Smart 3 5D Panel...
Page 22: ...800 WMAGNET 22 of 33 5 10 Main PC Board Figure 5 5 Main PC Board...
Page 30: ...800 WMAGNET 30 of 33 5 3 Remote Enclosure Dimensions Figure 5 12 Remote Enclosure BB 8783...
Page 31: ...800 WMAGNET 31 of 33 5 4 Remote Wiring Connections Figure 5 13 Remote Wiring Connections...
Page 34: ...1 800 W MAGNET WWW WALKERMAGNET COM 900632 A 07 21...