13
Walker Magnetics, Inc., NEO Permanent Lifting Magnets
NEO-125
LIFTING GUIDELINES
(ROUND BARS)
Values shown are for maximum rated capacities when operating instructions and warnings are followed.
VALUES ARE BASED UPON AISI 1020 STEEL
Higher alloy steels and other magnetic materials will require further reductions of these rated capacities
(See page 11 for the Guidelines for the reduction of the Rated Lifting Capacities.)
NEVER EXCEED EITHER THE MAXIMUM LENGTH OR WEIGHT SHOWN FOR EACH
ROUND BAR DIAMETER & TYPE OF SURFACE CONDITION
Round
Bar
Diameter
Inches
TYPE OF SURFACE CONDITION
CLEAN & SMOOTH
Similar to a Flat
(32 micro-inch RMS)
Ground Surface
RUST OR SCALE
Similar to a Flat Hot Rolled
Steel Surface
.010” Max. Air Gap †
(.254mm)
IRREGULAR OR ROUGH
Similar to a Flat Smooth
Cut File
.020” Max. Air Gap †
(.508mm)
Maximum
Length Inches
Maximum Load
Pounds
Maximum
Length Inches
Maximum Load
Pounds
Maximum
Length Inches
Maximum Load
Pounds
4”
(102mm)
MAX. DIA..
24”
88
17”
61
14”
50
3”
(76mm)
44”
88
30”
61
24”
50
2”
(51mm)
60”
60
54”
50
45”
40
NEVER LIFT ROUND BARS WITH:
A diameter LESS THAN 2.00 Inches or
A diameter GREATER THAN 4.00 Inches or
A length greater than shown in the Lifting Guidelines above
(Absolute maximum length 60” (1524mm))
† Air Gap = nonmagnetic separation between magnet’s lifting surface and load.