19
Walker Magnetics, Inc., NEO Permanent Lifting Magnets
NEO-1000
LIFTING GUIDELINES
(ROUND BARS & PIPES)
Values shown are for maximum rated capacities when operating instructions and warnings are
followed.
VALUES ARE BASED UPON AISI 1020 STEEL
Higher alloy steels and other magnetic materials will require further reductions of these rated
capacities (See page 11 for the Guidelines for the reduction of the Rated Lifting Capacities.)
NEVER EXCEED EITHER THE MAXIMUM LENGTH OR WEIGHT SHOWN FOR EACH
ROUND BAR/PIPE DIAMETER, WALL THICKNESS & TYPE OF SURFACE CONDITION
Round
Bar/Pipe
Diameter
Inches
Pipe
Wall
Thickness
Inches
TYPE OF SURFACE CONDITION
CLEAN & SMOOTH
Similar to a Flat
(32 micro-inch RMS)
Ground Surface
.000” Max. Air Gap †
RUST OR SCALE
Similar to a Flat Hot
Rolled
Steel Surface
.010” Max. Air Gap †
(.254mm)
IRREGULAR OR ROUGH
Similar to a Flat Smooth
Cut File
.020” Max. Air Gap †
(.508mm)
Maximum Length
Inches
Maximum Load
Pounds
Maximum Length
Inches
Maximum Load
Pounds
Maximum Length
Inches
Maximum Load
Pounds
11”
(279mm)
MAX. DIAM.
3/8”
31”
117
27”
97
21”
77
1/2”
39”
182
35”
163
30”
141
1”
66”
587
58”
522
50”
449
SOLID BAR
40”
1100
34”
925
26”
720
8”
(203mm)
3/8”
46”
117
38”
97
30”
77
1/2”
54”
182
49”
163
42”
140
SOLID BAR
77”
1100
65”
925
50”
720
6”
(152mm)
3/8”
62”
117
51”
97
41”
77
1/2”
74”
182
67”
163
58”
140
SOLID BAR
137”
1100
115”
925
90”
720
4”
(101mm)
3/8”
96”
117
80”
97
63”
77
1/2”
116”
182
105”
163
90”
140
SOLID BAR
177”
629
177”
629
177”
629
3”
(76mm)
MIN. DIAM.
3/8”
133”
117
110”
97
87”
77
1/2”
114”
127
102”
114
89”
99
SOLID BAR
177”
354
177”
354
177”
354
NEVER LIFT ROUND BARS OR PIPES WITH:
A diameter LESS THAN 3 Inches or
A diameter GREATER THAN 11 Inches or
A wall thickness LESS THAN 3/8” (9.5 mm) or
A length greater than shown in the Lifting Guidelines above
(Absolute maximum length 177” (4500mm)
† Air Gap = nonmagnetic separation between magnet’s lifting surface and load.