20
O.S. Walker Inc., NEO Permanent Lifting Magnets
NEO-2000
LIFTING GUIDELINES
(PLATE)
Values shown are for maximum rated capacities when operating instructions and warnings are
followed.
VALUES ARE BASED UPON AISI 1020 STEEL
Higher alloy steels and other magnetic materials will require further reductions of these rated
capacities (See page 11 for the Guidelines for the reduction of the Rated Lifting Capacities.)
NEVER EXCEED EITHER THE MAXIMUM WEIGHT OR SIZE SHOWN
FOR EACH LOAD THICKNESS AND TYPE OF SURFACE CONDITION
LOAD
THICKNESS
Inches
TYPE OF SURFACE CONDITION
CLEAN & SMOOTH
Similar to a Flat
(32 micro-inch RMS)
Ground Surface
.000” Max. Air Gap †
RUST OR SCALE
Similar to a Flat Hot Rolled
Steel Surface
.010” Max. Air Gap †
(.254mm)
IRREGULAR OR ROUGH
Similar to a Flat Smooth
Cut File
.020” Max. Air Gap †
(.508mm)
Maximum Load
Pounds
Maximum
Length Inches
Maximum Load
Pounds
Maximum
Length Inches
Maximum Load
Pounds
Maximum
Length Inches
4” & above
(100mm & above)
4400
(2000kg)
-
2860
(1300kg)
-
2420
(1100kg)
-
*2”
(51mm)
2750
(1250kg)
96 x 48
(2.4x1.2m)
2150
(980kg)
78x48
(1.95x1.2m)
1890
(860kg)
68x48
(1.7x1.2m)
*1”
(25.4mm)
1430
(650kg)
96 x 48
(2.4x1.2m)
1210
(550kg)
88x48
(2.2x1.2m)
1045
(475kg)
72x48
(1.8x1.2m)
*3/4”
(20mm)
880
(400kg)
96 x 42
(2.4 x 1.1m)
825
(375kg)
88 x 42
(2.2 x 1.1m)
770
(350kg)
72 x 48
(1.8x 1.2m)
NEVER LIFT ANY LOADS WITH ANY DIMENSION GREATER
THAN 96 INCHES (2.4 METERS)
OR WITH A THICKNESS LESS THAN 3/4” (20 mm)
† Air Gap = nonmagnetic separation between magnet’s lifting surface and load.
* Lifting capacity affected by peel and thickness. See notes 2 & 4 in the “Important
Facts” and “Recommended Lifting Procedures” (See pages 6, 7 and 10).