21
Walker Magnetics, Inc., NEO Permanent Lifting Magnets
NEO-2000
LIFTING GUIDELINES
(ROUND BARS & PIPES)
Values shown are for maximum rated capacities when operating instructions and warnings are
followed.
VALUES ARE BASED UPON AISI 1020 STEEL
Higher alloy steels and other magnetic materials will require further reductions of these rated
capacities (See page 11 for the Guidelines for the reduction of the Rated Lifting Capacities.)
NEVER EXCEED EITHER THE MAXIMUM LENGTH OR WEIGHT SHOWN FOR EACH
ROUND BAR/PIPE DIAMETER, WALL THICKNESS & TYPE OF SURFACE CONDITION
Round
Bar/Pipe
Diameter
Inches
Pipe
Wall
Thickness
Inches
TYPE OF SURFACE CONDITION
CLEAN & SMOOTH
Similar to a Flat
(32 micro-inch RMS)
Ground Surface
.000” Max. Air Gap †
RUST OR SCALE
Similar to a Flat Hot Rolled
Steel Surface
.010” Max. Air Gap †
(.254mm)
IRREGULAR OR ROUGH
Similar to a Flat Smooth
Cut File
.020” Max. Air Gap †
(.508mm)
Maximum Length
Inches
Maximum Load
Pounds
Maximum Length
Inches
Maximum Load
Pounds
Maximum Length
Inches
Maximum Load
Pounds
13.75”
(350mm)
MAX DIAM.
3/4”
51”
440
48”
412
44”
385
1”
63”
715
53”
605
46”
522
SOLID BAR
52”
2200
47”
1980
42”
1760
11”
(279 mm)
3/4”
64”
440
60”
412
56”
385
1”
80”
715
68”
605
59”
522
SOLID BAR
82”
2200
74”
1980
65”
1760
8.625”
(220mm)
3/4”
84”
440
78”
412
73”
385
1”
105”
715
89”
605
77”
522
SOLID BAR
133”
2200
120”
1980
106”
1760
8”
(203mm)
3/4”
91”
440
85”
412
80”
385
1”
115”
715
97”
605
84”
522
SOLID BAR
155”
2200
139”
1980
124”
1760
6”
(152mm)
MIN DIAM.
3/4”
126”
440
118”
412
110”
385
1”
160”
715
136”
605
117”
522
SOLID BAR
196”
1570
177”
1415
157”
1255
NEVER LIFT ROUND BARS OR PIPES WITH:
A diameter LESS THAN 6 Inches or
A diameter GREATER THAN 13.75 Inches or
A wall thickness LESS THAN 3/4” (20 mm) or
A length greater than shown in the Lifting Guidelines above
(Absolute maximum length 196” (5000mm)
† Air Gap = nonmagnetic separation between magnet’s lifting surface and load.