background image

Signal effective 

distance

Approx. 6 km (open and unobstructed, no 

electromagnetic interference)

7.4V 9000mAh LiPo 2S

Mini HDMI

Supports microSD cards up to 64GB capacity

Video output 

interface

Memory card type

Battery

Screen

Remote Controller

7.86inch; Resolution: 2048× 1536; Brightness: 2000 cd/m

2

2.4GHz&5.8GHz dual-band

RAM:  4G; ROM:  16G

Android 

Memory

System

Operating 

frequency

Distance 

measuring range

LIDAR Ranging & Obstacle Avoidance System

100m

3~15m (adjustable)

 Obstacle 

perception range

FOV

Horizontal 20°, vertical 3°

10kHz

Measuring 

frequency

PTZ Camera System with 3-Axis Gimbal

4K 30fps

6.7-134.5mm

5000Mm (wide Angle - telescopic)

Max. 64 Mbps

H.264 / H.265

File system: FAT32; Image format: JPG;

Video format: MP4

Micro-SD card up to 128G with a transfer rate of 

Class 10 and above or UHS-1 rating

3840×2160

30 X optical zoom

Appr. 2.0 seconds

59.8 ° ~ 3.0 ° (wide Angle - telescopic)

Video storage 

code stream

Photograph 

resolution

Focal length

Zoom 

magnification

Zoom speed

Horizontal 

angle of view

Close up 

distance

Video 

recording 

resolution

Compression 

standard

Supported file 

storage 

formats

Supported 

memory 

card types

Size

136×98×139mm

12V

Pitch:30°/s; yaw:30°/s

12 million

2s

1/2.3 SONY IMX117 CMOS

Video: 100

3200; photo: 100

1600

452g

3 axis (pitch, roll, yaw)

Static: ±0.008°; Dynamic: ±0.02°; 

Anti-shake: ±0.008°

Pitch: -110° ~+60°; Yaw: ±150°; Roll: ±10°

Weight

Input voltage

Stability 

system

Angle control 

accuracy

Controllable 

rotation 

range

Max control 

speed

Pixels

Focus time

Sensor

ISO range

Gimbal

Surveillance camera

Surveillance camera

9

Walkera All Rights Reserved

WK-1800

 Airborne dry powder fire extinguisher

 

, Fire Hose Fire Fighting UAV Quick Start Guide

Diameter

Pressure

25mm

2.0MPa

100m

Length

Fire hose specifications

Material

Carbon fiber

3.04M un-telescoped 

(can be telescoped 

to 1.61m minimum)

Length

Fire Extinguishing System

Fire hose 

fire 

extinguishing 

system

Jet pipe

HP295

Material

19kg

12kg

Total 

weight

Filling 

pressure

Installation 

method

Open 

method

Electronically 

controlled quick 

opening

Fast 

hanging

Net dry powder 

content

1.2MPa

Dry powder tank 

Material

Carbon fiber

4.33M un-telescoped 

(can be telescoped 

to 1.61m minimum)

Length

Fire 

Suppression 

tank 

system

Jet pipe

Summary of Contents for ZHUN WK-1800

Page 1: ...www walkera com WK 1800 Fire Fighting UAV Airborne Fire Hose Airborne dry powder fire extinguisher QUICK START GUIDE V1 0 Aug 18th 2020...

Page 2: ......

Page 3: ...signal indications 10 5 Unlock lock the motor 11 0 Flight control 12 0 Gimbal Control 13 0 Photo Video 14 0 End Flight 15 0 Preparation for Fire Fighting 15 1 Install airborne fire hose assembly 15 2...

Page 4: ...mera and fire extinguisher launcher are firmly installed and all screws are locked Make sure the propeller is firmly installed without damage and the arm is fully deployed and tightened Make sure the...

Page 5: ...a reserves the right to update revise or discontinue these terms and conditions at any time without prior notice In order to avoid violations possible injuries and damages the following must be observ...

Page 6: ...er than 10 2 Do not expose the camera to liquid or immerse it in water If the camera is immersed in water please wipe it off immediately with a dry fluffy cloth Do not turn on the power immediately af...

Page 7: ...h to turn on the remote control Power off restart Press and hold the power switch and the Power Off and Restart operation interface will pop up on the remote control screen Tap Power Off to turn off t...

Page 8: ...rn Right Left Right Fig 3 0 3 Fig 3 0 5 Forward Backward Tilt Left Tilt Right Fig 3 0 6 Fig 3 0 4 8 Walkera All Rights Reserved WK 1800 Airborne dry powder fire extinguisher Fire Hose Fire Fighting UA...

Page 9: ...ew Close up distance Video recording resolution Compression standard Supported file storage formats Supported memory card types Size 136 98 139mm 12V Pitch 30 s yaw 30 s 12 million 2s 1 2 3 SONY IMX11...

Page 10: ...etion indicator is on it means it is fully charged 6 1 Charge the remote control There are two ways to charge the remote control battery rechargeable battery Method one Without removing the battery us...

Page 11: ...ck Start Guide 6 2 Charge the aircraft lithium battery Battery Type LiPo LiHV Charging current 1 0 12 0 A Charging mode fast charge precise charge battery storage Sync status Off line Master Slave 12...

Page 12: ...racy of the aircraft 7 HD image transmission signal strength Display the strength of the video signal transmitted between the aircraft and the remote control 8 Remote signal strength Display the contr...

Page 13: ...nd adjust their position Fig 8 0 1 Fig 8 0 2 Strong Weak 13 Walkera All Rights Reserved WK 1800 Airborne dry powder fire extinguisher Fire Hose Fire Fighting UAV Quick Start Guide 8 0 Prepare the Remo...

Page 14: ...rm latches inwards in turn and then expand the arm upwards Then turn the arm lock to the side and snap it into the arm buckle then press the arm fastener firmly Rotate the paddles outward as indicated...

Page 15: ...e tail of the aircraft Place the aircraft in a horizontal position and the green LED light will change from fast flashing to slow flashing to indicate successful code matching Check connection status...

Page 16: ...on the map interface is pointing in the same direction as the actual drone s nose Fig 10 5 1 Fig 10 4 When the aircraft is landed push the throttle stick down to the lowest position and hold it for 5...

Page 17: ...he throttle stick down to the lowest position and hold it for 5 seconds The motors will then stop Flight mode switch In GPS mode short press the automatic take off and landing button D key the aircraf...

Page 18: ...dry powder fire extinguisher Fire Hose Fire Fighting UAV Quick Start Guide You can only enter the route flight and route planning interfaces when the aircraft is in GPS mode Click this icon to add wa...

Page 19: ...automatically land from the current position During the landing you can control the throttle and direction Attentions 1 Do not operate other switches or buttons after pressing the RTH button 2 When th...

Page 20: ...eed is 0 when it returns to the midpoint the larger the amplitude the faster the change of the Gimbal system and the opposite is slower WKRC H15Z Waypoint GPS Manual Take o Landing C Power RTH D D N G...

Page 21: ...ng holes and insert it into mounting holes 21 Walkera All Rights Reserved WK 1800 Airborne dry powder fire extinguisher Fire Hose Fire Fighting UAV Quick Start Guide 15 1 Install airborne fire hose as...

Page 22: ...clockwise and then stretch the nozzle forward until it is fully extended 5 The locking lance and aligned mounting holes into the mounting holes 6 7 15 2 Installation of airborne dry powder fire exting...

Page 23: ...Mode 18 2 4G 98 51 98V GPS Ready 15 m D H H S V S 17 1 m 0 0 m s 0 0 m s P 0 0 R 0 0 Y 0 0 Center Down N 16 1 Fire fighting with airborne fire hose 1 First connect the fire hose to a high pressure fir...

Page 24: ...123E 22 06 0902N Connected GPS 03 58 45 AUTO Mode 18 2 4G 98 51 98V GPS Ready 15 m D H H S V S 17 1 m 0 0 m s 0 0 m s P 0 0 R 0 0 Y 0 0 Center Down N Fig 17 1 1 24 Walkera All Rights Reserved WK 1800...

Page 25: ...example of setting the safety distance to obstacle at x m Fig 17 1 5 25 Walkera All Rights Reserved WK 1800 Airborne dry powder fire extinguisher Fire Hose Fire Fighting UAV Quick Start Guide 2 First...

Page 26: ...mode you want 26 Walkera All Rights Reserved WK 1800 Airborne dry powder fire extinguisher Fire Hose Fire Fighting UAV Quick Start Guide Operations 17 4 Installation and use of megaphone Transmitter...

Page 27: ...objects on the battery or charger 9 Do not disassemble or modify the battery or use it for other purposes 10 Use the original charger to charge the battery according to the standard procedure 11 Recha...

Page 28: ...o Ltd Add No 48 Wantai Rd Taishi Industrial Park Dongchong Town Nansha Dist Guangzhou China 511453 Hotline 86 20 84915115 This manual is subject to update without prior written notice Please refer to...

Reviews: