102
wallaceperimetersecurity.com
Phone: 866.300.1110
PRIMARY AND SECONDARY WIRING CONNECTIONS
Primary and Secondary Wiring Connections
Figure 18
.
Primary and Secondary Connections
1�
As shown in Figure 18, connect a shielded communications cable to the DUAL GATE inputs in each
unit. The inputs are located near the base of the SmartDC Controller. Be sure to connect the
wires in pairs to the same terminal ports (A-A, B-B, and COM to COM) on both units. See Primary
Secondary Connections on SDC Boards - Table 10.
Secondary
Primary
A
A
COM
COM
B
B
Shield wire to ground.
Only ground to one
unit. Do NOT attach
the shield wire to
both units.
2�
Attach a ring terminal to the shield wire and connect it to the SmartDC Controller’s convenient
ground screw. Refer to Figure 18.
Table 10. Primary Secondary Connections on SDC Boards
Connect the ground shield wire to
only one operator, not both.