INSTALLING A LOCK FOR HIGH VOLTAGE SYSTEMS
Installing a Lock for High Voltage Systems
To install a lock on higher voltage systems
(115V or 230V), take the following steps:
1�
Connect one lead of the power
supply to one lead of the lock’s coil.
See Figure 21.
2�
Connect the other lead of the lock’s
coil to NO on USER 1 RELAY.
Connect to NC on USER 1 RELAY if installing
a maglock.
3. Connect the COM on USER 1 RELAY
to the second lead wire in the power
supply (115V or 230V).
4�
Set the User Relay function in the
Installer Menu to RL1 - 6. Refer to
“Setting the User Relay Function in
the Installer Menu” on page 108
Figure 21
.
Lock on High Voltage Systems