SMARTDC CONTROLLER TROUBLESHOOTING
Table 11. SmartDC Controller - Troubleshooting
Table 11. SmartDC Controller - Troubleshooting
Ref.
No�
Display
Description
Possible Causes
Solutions
Condition
Alert, Error or Fault
3
NO AC POWER
No AC Input Power.
Advisory only.
AC power is shut off at the
source (breaker) or is not
connected. The AC power
switch on the operator
(lower rocker switch) is
turned off, or the circuit
breaker on the operator
has tripped.
1.
Turn AC power switch on
or connect power to the
operator.
2.
Reset the operator circuit
breaker or connect power
to AC switch.
3.
Reset circuit breaker at
electrical panel.
4.
Have a licensed electrician
check the wiring.
4
LOW 24VDC
Low 24VDC UPS
Batteries.
Advisory only.
Occurs when the battery
voltage has dropped to less
than 22V. At this level, the
batteries are 80% depleted.
Normal function until 21V.
1.
No AC Power. See item 3
above.
2.
Wiring / Connector
problem – check all
connections. Clean or
repair as required.
3.
Check battery condition.
4. SmartDC Controller
charger failure – check
charger voltage and
replace SmartDC
Controller.
5.
Transformer failure –
replace Transformer.
5
DEAD BATTERY
Extremely low UPS
batteries – no automatic
operation – batteries
below 21V.
Occurs when the battery
voltage has dropped to less
than 21V. At this level, the
batteries are 90% depleted.
The gate will automatically
open or close depending
upon the setting chosen.
Refer to
automatic function is
possible, but limited push-
button control is available
to 18V.
1.
No AC Power. See item 3
above.
2.
Wiring / Connector
problem – check all
connections. Clean or
repair as required.
3.
Check battery condition.
4. SmartDC Controller
charger failure – check
charger voltage and
replace SmartDC
Controller.
5.
Transformer failure –
replace Transformer.
Summary of Contents for FOLDSMART
Page 36: ...36 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 38: ...38 wallaceperimetersecurity com Phone 866 300 1110 FOLDSMART GATE INSTALLATION ...
Page 146: ......
Page 147: ...FoldSmart XT Drawings Generic Site Layout and Options ...
Page 148: ......
Page 149: ......
Page 150: ......
Page 151: ......
Page 152: ......
Page 153: ......
Page 154: ......
Page 155: ......
Page 156: ......
Page 157: ......
Page 158: ......
Page 160: ......